3.6
Restart interlock
The tool doesn't restart automatically when the power returns after an interruption in the supply. The on/off
switch must first be released and then pressed again to restart.
3.7
Items supplied
Breaker, side handle, operating instructions.
You can find other system products approved for your product at your local Hilti Center or online at:
www.hilti.com
4
Technical data
4.1
Breaker
For details of the rated voltage, frequency, current and input power, please refer to the power tool's
country-specific type identification plate.
When powered by a generator or transformer, the generator or transformer's power output must be at least
twice the rated input power shown on the rating plate of the power tool. The operating voltage of the
transformer or generator must always be within +5% and -15% of the rated voltage of the power tool.
Single impact energy in accordance with EPTA procedure 05/2009 11.5 J
Weight in accordance with EPTA procedure 01
4.2
Noise information and vibration values in accordance with EN 62841
The sound pressure and vibration values given in these instructions were measured in accordance with a
standardized test and can be used to compare one power tool with another. They can also be used for a
preliminary assessment of exposure.
The data given represent the main applications of the power tool. However, if the power tool is used for
different applications, with different accessory tools, or is poorly maintained, the data can vary. This can
significantly increase exposure over the total working period.
An accurate estimation of exposure should also take into account the times when the power tool is switched
off, or when it is running but not actually being used for a job. This can significantly reduce exposure over
the total working period.
Identify additional safety measures to protect the operator from the effects of noise and/or vibration, for
example: maintaining the power tool and accessory tools, keeping the hands warm, organization of work
patterns.
Noise information
Sound power level (L
WA
Emission sound pressure level (L
Uncertainty (noise values) (K
Total vibration
Chiseling (a
)
h, Cheq
Uncertainty (total vibration)
5
Operation
5.1
Preparations at the workplace
CAUTION
Risk of injury! Inadvertent starting of the product.
▶ Unplug the supply cord before making adjustments to the power tool or before changing accessories.
Observe the safety instructions and warnings in this documentation and on the product.
16
English
)
)
pA
and K
)
pA
WA
7.9 kg
94 dB(A)
83 dB(A)
3 dB(A)
6.9 m/s²
1.5 m/s²
428077