Herunterladen Inhalt Inhalt Diese Seite drucken

Balluff BOS R254K-UUI-RH11-S4 Konfigurationsanleitung Seite 205

Vorschau ausblenden Andere Handbücher für BOS R254K-UUI-RH11-S4:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BOS R254K-UUI-RH11-S4
Photoelectric Sensors
7
System Functions (continued)
7.6
LED Meaning and Configuration
7.6.1
Description
Only the signal with the highest priority is displayed. The
signals are listed in descending priority.
Balluff Standard
LED 1 (operating status and communication)
Name
Failure
Communication
Ready
Tab. 7-18: LED meaning and configuration – Balluff Standard, LED1
LED 2 (Indication/Warning/Teach/Device Discovery)
Name
Device Discovery
Short Circuit Pin 2 / Pin 4
Teach-in No Object
Teach-in
Maintenance Required
Bad Signal Quality
Out of Specification
Function Display
Tab. 7-19: LED meaning and configuration – Balluff Standard, LED2
www.balluff.com
Signal
Static red
Green alternating with LED
off at ratio of 10:1, 1 s
period
Static green
Signal
Blue, flashing, 3 Hz
Red, flashing, 3 Hz
Red, flashing, 1 Hz
Static red
Blue, static
Orange, flashing, 1 Hz
Yellow, flashing, 3 Hz
Yellow, static
Meaning
General error
IO-Link communication is active. The device is ready.
The device is ready.
Meaning
The Device Discovery can be activated via a system
command to find the device again.
Short circuit at pin 2 or pin 4
The sensor is in Teach-In mode and no object is visible.
Teaching is not possible.
The device is currently in teach-in mode
Maintenance must be performed.
Poor signal quality, the signal quality is below the
configured warning threshold.
The device is operated outside of specifications. A
reliable measurement signal can no longer be ensured.
The object was detected / switching point is active
english
97

Werbung

Inhaltsverzeichnis
loading