Identification

3 Identification
Please check the particular type of unit and type number from the identifi-
cation plate. Type number and the corresponding version are indicated in
the delivery documentation.
e. g.

4 Installation

4.1 Mechanical mounting

Inclinometer failure
CAUTION
` When mounting pay attention to the IP type of protection (see chap-
` Do not open the inclinometer yourself.
` Avoid impact on the device.
` Do not modify the device in any way.
An electrical connection must be established between the sensor and the
NOTICE
mounting point. Since the sensor housing is made of anodized aluminum,
each screw must be underlaid with a serrated underplate, V2A according
to DIN 6797.
Ensure that the sensor is mounted in such a way that the correct measur-
NOTICE
ing axes are detected.
The IMS360 is a pre-calibrated instrument that can be put into operation
immediately. The mounting area must be level, free from dust and grease.
Use 3 pieces of M5 cap screws and serrated washers for fastening. Observe
the uniform tightening torque of the screws. Take care to mount the incli-
nometer free from distortion.
The side with the marked axes and the identification plate is the inclinom-
eter's upper side.