8008782.1DMA/2022-07-12 | SICK
Subject to change without notice
2
Sensing range
Observe application conditions: adjust the distance between the sensor and the reflector
according to the corresponding diagram [see
reserve).
If several through-beam photoelectric sensors which are installed next to one another are
to be used, we recommend swapping the sender/receiver arrangement at every second
through-beam photoelectric sensor and ensuring that there is sufficient distance between
the through-beam photoelectric sensors. By doing this, mutual interference can be pre‐
vented [see
figure
1].
100
10
sensing range
typ. max. sensing range
1
m
10
20
30
Figure 5: Characteristics
3
Sensitivity setting
Sensor with potentiometer: open the sensor cover and protective hood, make sure that no
dirt has gotten into the sensor.
The sensitivity is adjusted with the potentiometer (type: without stop). Clockwise rotation:
operating reserve increased; counterclockwise rotation: operating reserve reduced. We
recommend setting the potentiometer to "Maximum".
The sensor is adjusted and ready for operation.
4
Time function setting
WSE24-2xx4x: t0= no time delay, t1 = time delay, t2 = time delay; for -2R: 0 = relay
deactivated, 1 = relay active. Time delay selector switch can be set on the device according
to the following graphic.
Time stages: 0.5 ... 10 s can be adjusted.
0
+
1
2
Figure 7: Time functions
OPERATING INSTRUCTIONS
figure
5] (x = sensing range, y = operating
0
0
Sensing range
40
50
60
0.5 ... 10 sec.
0.5 ... 10 sec.
0.5 ... 10 sec.
O P E R A T I N G I N S T R U C T I O N S | WS/WE24-2
50
60
10
20
30
40
50
(32.81)
(65.62)
(98.43)
(131.23)
(164.04)
(196.85)
Distance in m (feet)
Sensing range max.
Figure 6: Bar graph
60
en