Safety Switch STP-TW... (Twin)
4. Stop the machine function and release guard
locking.
The guard must remain locked until there is no
¨
longer any risk of injury (e.g. due to movements
with overtravel).
It must not be possible to start the machine
¨
function as long as guard locking is released.
Repeat steps 2 - 4 for each guard.

Inspection and service

WARNING
Danger of severe injuries due to the loss of the
safety function.
If damage or wear is found, the complete switch
f
and actuator assembly must be replaced. Re-
placement of individual parts or assemblies is
not permitted.
Check the device for proper function at regular
f
intervals and after every fault. For informa-
tion about possible time intervals, refer to
EN ISO 14119:2013, section 8.2.
Inspection of the following is necessary to ensure
trouble-free long-term operation:
correct switching function
f
secure mounting of all components
f
damage, heavy contamination, dirt and wear
f
sealing of cable entry
f
loose cable connections or plug connectors.
f
Info: The year of manufacture can be seen in the
bottom, right corner of the type label.

Exclusion of liability and warranty

In case of failure to comply with the conditions for
correct use stated above, or if the safety regula-
tions are not followed, or if any servicing is not
performed as required, liability will be excluded and
the warranty void.
Notes about
The following information applies to devices
with cable entry:
For use and application as per the requirements
of
a copper wire for the temperature range
60/75 °C must be used.
The following information applies to devices
with plug connector:
This device is intended to be used and applied with
a Class 2 power source in accordance with UL1310.
Connecting cables for safety switches installed at
the place of use must be separated from all moving
and permanently installed cables and un-insulated
active elements of other parts of the system that
operate at a voltage of over 150  V. A constant
clearance of 50.8 mm must be maintained. This
does not apply if the moving cables are equipped
with suitable insulation materials that possess an
identical or higher dielectric strength compared to
the other relevant parts of the system.

EU declaration of conformity

The declaration of conformity is part of the operating
instructions.
The complete EU declaration of conformity can also
be found at www.euchner.com. Enter the order num-
ber of your device in the search box. The document
is available under Downloads.
Service
If servicing is required, please contact:
EUCHNER GmbH + Co. KG
Kohlhammerstraße 16
70771 Leinfelden-Echterdingen
Germany
Service telephone:
+49 711 7597-500
E-mail:
support@euchner.de
Internet:
www.euchner.com

Technical data

Parameter
Value date
Housing material
Reinforced thermoplastic
Degree of protection acc. to
IEC 60529
Cable entry
IP67
Plug connector SR11
IP65
Mechanical life
1 x 10
operating cycles
6
Ambient temperature
-20 ... +55 °C
Degree of contamination
3 (industrial)
(external, acc. to EN 60947-1)
Installation orientation
Any
Approach speed, max.
20 m/min
Extraction force (not locked)
30 N
Retention force
20 N
Actuating force, max.
35 N
Actuation frequency
1,200/h
Switching principle
Slow-action switching contact
Contact material
Silver alloy, gold flashed
Connection
STP...
Cable entry M20 x 1.5 (screw
terminal)
STP...SR11
Plug connector SR11, 11-pin+PE
(PE not connected)
Conductor cross-section
0.34 ... 1.5 mm²
(flexible/rigid)
Operating voltage for optional
L024 24 V
LED indicator
Rated insulation voltage
STP...
U
= 250 V
i
STP...SR11
U
= 50 V
i
Rated impulse withstand voltage
STP...
U
= 2.5 kV
imp
STP...SR11
U
= 1.5 kV
imp
Conditional short-circuit
100 A
current
Switching voltage, min.,
12 V
at 10 mA
Utilization category acc. to EN 60947-5-1
STP...
AC-15 4 A 230 V /
DC-13 4 A 24 V
STP...SR11
AC-15 4 A 50 V /
DC-13 4 A 24 V
Short circuit protection
(control circuit fuse) acc. to
4 A gG
IEC 60269-1
Convent. thermal current I
4 A
th
Solenoid operating voltage/solenoid power consumption
STP...024
AC/DC 24 V (+10%/-15%) 8 W
STP...048
AC/DC 48 V (+10%/-15%) 8 W
STP...110
AC
110 V (+10%/-15%) 10 W
STP...230
AC
230 V (+10%/-15%) 11 W
Duty cycle
100%
Locking force
F
max
ACTUATOR S-G...,
HINGED ACTUATOR S-...
2,500 N
ACTUATOR S-WQ-...
2,000 N
ACTUATOR S-W-...
1,500 N
ACTUATOR S-WT-...,
ACTUATOR S-WQT-...
1,000 N
Reliability values acc. to EN ISO 13849-1
B
4.5 x 10
10D
6
at DC-13 100 mA / 24 V
1) Refer to the EU declaration of conformity for the issue date
8
F
Zh
2,000 N
1,500 N
1,100 N
700 N
1)