9. Select the next menu item to be changed by turning
the info button.
10. Turn the info button until the "Save?" menu item is
displayed.
11. Press the Info button.
The settings are saved.
12. Turn the info button until the "Quit Menu?" menu
item is displayed.
13. Press the Info button.
Operation with the white Intelligent Key
1. Insert the white Intelligent Key.
● The "OFF", travel and vacuum functions work as
usual.
● In all other positions of the program selection switch,
the parameters programmed on the white Intelligent
Key are active. Different cleaning programmes can
no longer be selected.

Transport

DANGER
Driving on slopes
Risk of injury
Observe the maximum permissible gradient when oper-
ating the device on slopes for loading and unloading
purposes (see chapter "Technical data").
Always press the brake pedal to reduce speed.
CAUTION
Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during transporta-
tion.
1. With the D cleaning head installed, remove the disc
brushes from the brush head.
2. When transporting in vehicles, secure the device
against slipping and tipping over according to the
applicable guidelines.

Storage

CAUTION
Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during storage.
ATTENTION
Frost
Destruction of the device through freezing water
Drain all water from the device.
Store the device in a frost-free location.
When choosing the parking space, take into account the
total weight of the device in order not to impair its stabil-
ity.
● This device may only be stored indoors.
● Fully charge the batteries before storing them for a
long period.
● Fully charge the batteries at least every month dur-
ing storage.

Care and maintenance

DANGER
Risk of injury from the device!
Risk of injury due to device inadvertently starting up.
Turn the program switch to the "0" position.
Remove the Intelligent Key prior to all work on the de-
vice.
Pull out the charger mains plug.
Unplug the battery connector.
WARNING
Risk of injury from moving elements!
The suction turbine, side brushes and filter dedusting
run on after switching off.
Do not carry out any work on the device until the com-
ponents have come to a standstill.
 Drain and dispose of the waste water and fresh wa-
ter.
Maintenance intervals
Each time after use
ATTENTION
Risk of damage!
Risk of damage to the device due to improper cleaning.
Do not spray the device with water and do not use ag-
gressive detergents.
A detailed description of the individual maintenance
work is provided in chapter Maintenance work.
 Drain the waste water.
 Check the lint filter and clean if necessary.
 Pull out, empty and clean the waste container.
 Only with R cleaning head: Remove the coarse dirt
container and empty it.
 Clean the exterior of the device using a damp cloth,
wetted with a mild washing lye.
 Check the suction lips, check for wear and replace if
necessary.
 Clean the squeegee blades, check for wear and re-
place if necessary.
 Clean the brushes, check for wear and replace if
necessary.
Note
The roller brushes are worn out if the yellow indicator
bristles are the same length as the other bristles.
 Charge the battery.
 If the charging state of the battery is below 50%,
charge the battery fully and without interruption.
 If the charging state of the battery is above 50%,
only recharge the battery if the entire operating
duration will be required when next used.
 Clean the waste water tank if heavily soiled.
Additionally for the Combo variant:
 Check the roller brush and side brushes for wear
and tear, foreign objects and any tangled pieces of
tape.
 Pull out, empty and clean the coarse dirt basket.
Weekly
 When used regularly, charge the battery fully and
without interruption at least once a week.
Monthly
 If the device is temporarily shut down (storage): Per-
form equalization charging of the battery.
 Check battery poles for oxidation, brush off if neces-
sary. Make sure the connection cables are firmly in
place.
 Clean the seals between the waste water tank and
the cover, check for leaks and replace if necessary.
 Check the acid density of the cells if the batteries are
not maintenance-free.
 Only with R cleaning head: Clean the brush tunnel.
 For longer downtimes, shut down the device with
fully charged batteries. Fully charge the battery at
least once a month.
Additionally for the Combo variant:
 Check all Bowden cables and moving parts for ease
of motion.
 Check the sweeping mechanism sealing strips for
correct adjustment and for wear and tear.
Quarter-yearly
Only for the Combo variant:
1. Check the tension, wear and tear and function of the
drive belts in the sweeping mechanism (V-belts and
round belts).
Annually
 Have the prescribed inspection performed by Cus-
tomer Service.
Safety inspection/maintenance contract
You can agree on regular safety inspections or close a
maintenance contract with your dealer. Please seek ad-
vice on this.
Maintenance work
Cleaning the waste water tank
1. Set the program Tank rinsing via the display using
the info button.
2. Open the lid of the waste water tank detergent filling
opening.
3. Rinse the waste water tank with clear water.
4. Clean the edge of the cleaning opening.
5. Close the lid of the waste water tank cleaning open-
ing again.
Note
Cleaning can also be performed using other water
sources.
Turning over or replacing the suction lips
The suction lips must be turned over or replaced when
worn out.
Note
The suction lips can be turned 3 times until all 4 edges
are worn.
1. Open the eccentric levers (2x).
2. Remove the suction bar.
Illustration V
Squeegee blade
1
Strap
2
Eccentric levers (2x)
3
Tension lock
4
3. Open the tension lock.
4. Remove the strap.
5. Remove the squeegee blade.
6. Press the turned or new suction lips onto the knobs
of the inner part of the suction bar.
Illustration W
Strap
1
Squeegee blade
2
English
7. Attach the strap.
8. Fit the suction bar
9. Close the eccentric levers (2x).
Replacing the roller brushes
1. Pull the tab.
Illustration Z
Tab
1
2. Pivot open the squeegee blade side doors.
Squeegee blade side doors
1
3. Pivot the yellow lever upwards.
Illustration AA
Bar
1
Safety flap
2
4. Pivot away the safety flap.
5. Pull off the brush retaining plate.
6. Remove the roller brush.
7. Fit the new roller brush.
Note
When fitting the roller brush, note that it must be placed
on the PIN provided in the brush tunnel.
Illustration AB
PIN
1
8. Fit the brush retaining plate again.
9. Close the safety flap.
10. Pivot the latch downwards into the hook.
11. Pivot the squeegee blade side door closed.
Repeat the entire procedure at the other side.
Replacing squeegee blades
Illustration AG
Tab
1
Squeegee blade side doors
2
1. Pull the tab.
2. Pivot open the squeegee blade side doors.
3. Unscrew the screws (6x).
Illustration AH
4. Replace the squeegee blade.
5. Reinstall the screws (6x).
6. Close the squeegee blade holder again.
Replacing the disc brushes
1. Pull the tab on the side doors.
Illustration AF
Bracket
1
2. Pivot open the squeegee blade side doors.
3. Push the bracket downwards.
4. Pull the disc brush sideways and out from under-
neath the cleaning head.
5. Hold the new disc brush under the cleaning head,
then press upwards and latch it into position.
6. Pivot the squeegee blade side doors closed again.
Additional maintenance work on the side
scrubbing deck
Cleaning the brush
1. Turn the brush clockwise until the brush
holder springs are facing forward.
2. Pull the brush holder springs apart.
Illustration AQ
Brush holder springs
1
The brush falls out of the holder.
3. Check the brush for foreign objects (e.g. parcel tape
or foil).
4. Clean the brush under running water.
5. Pull the brush holder springs apart and fit the brush.
Checking the brush for wear and tear
The brush is worn out when the bristle length corre-
sponds to the length of the yellow indicator bristle.
1. Replace the brush (See Replacing the brush).
Replacing the brush
1. Turn the brush clockwise until the brush
holder springs are facing forward.
2. Pull the brush holder springs apart.
Illustration AQ
Brush holder springs
1
The brush falls out of the holder.
3. Fit the new brush.
4. Pull the brush holder springs apart and fit the brush.
23