AXIS P3365–V Fixed Dome Network Camera
Specifications

Operating Conditions

The Axis product is intended for indoor use.
Product
AXIS P3365–V

Power Consumption

Product
AXIS P3365–V
Connectors
I/O Connector
4-pin terminal block for:
• Auxiliary power (DC output)
• Digital Input
• Digital Output
• 0 V DC (-)
Function
Pin
1
0 V DC (-)
2
DC output
3
Digital Input
4
Digital
Output
Temperature
Classification
IEC 62262 IK10
-0 °C to 50 °C (32 °F
to 122 °F)
PoE
Power over Ethernet (PoE) IEEE 802.3af/802.3at Type 1 Class 2
Notes
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
Connect to pin 1 to activate, or leave floating
(unconnected) to deactivate
Connected to pin 1 when activated, floating
(unconnected) when deactivated. If used
with an inductive load, e.g. a relay, a diode
must be connected in parallel with the load,
for protection against voltage transients.
Humidity
15-85% RH (non-condensing)
1
2 3 4
13
Specifications
0 V DC
3.3 V DC
Max load = 50 mA
0 to max 40 V DC
0 to max 40 V DC, open
drain, 100 mA