During longer breaks, vent the container by briefly opening and then closing it again.
Clean nozzle openings after an interruption in operation.
When processing 2-component varnishes, clean the device immediately.

18. Taking Out of Operation and Cleaning

Proper cleaning is the prerequisite for problem-free operation of the paint application
device. No warranty claims are accepted in case of improper or no cleaning.
Never hold the spray gun rear part under water or immerse it into liquids.
Clean the housing only with a moistened cloth.
1) Turn the machine off. Vent the container in case of longer breaks and after the work
has been terminated. This can be done by briefly turning open and then closing the
container or by pulling the trigger guard and letting the paint into the original paint
container.
2) Divide the spray gun. Press the hook (Fig. 3 b "click") slightly downwards. Turn the gun
front part and gun rear part against each other and take them apart.
3) Unscrew the container. Empty any remaining coating material back into the material
tin.
4) Pull out the suction tube with container seal.
5) Preclean the container and suction tube with a brush. Clean the ventilating bore
(Fig.  14,  1).
19. Cleaning the Wall Extra I-Spray spray
attachment
CAUTION!
Never clean seals, diaphragm and nozzle or air holes of the spray gun with
metal objects. The ventilation hose and diaphragm are only solvent-resistant
to a limited extent. Do not immerse in solvent, only wipe.
1) The unit may only be operated with an integer diaphragm (Fig. 15, 3). If any
paint has penetrated to the ventilation hose, check and clean the membrane (see the
Maintenance chapter).
2) Move the air cap (Fig. 16, 1) to the vertical position for easier removal and lift it off.
3) Unscrew the union nut (fig. 16, 2). Clean the air cap (1) and nozzle (3) with a brush and
solvent or water.
Attention! Never remove the red nozzle seal from the nozzle. If the nozzle
seal is either missing or damaged liquids can enter the device and increase
the risk of an electric shock.
4) Clean the outside of the spray gun and container with a cloth soaked in solvent or
water.
5) Assemble the parts again (see "Assembly").