Heating - Information requirements for heat pumps
Indoor unit(s)
Model(s):
Outdoor unit
Outdoor side heat exchanger of heat pump: Air
Indoor side heat exchanger of heat pump: Air
Indication if the heater is equipped with a supplementary heater: no
If applicable: driver of compressor: electric motor
Parameters shall be declared for the average heating season, parameters for the warmer and colder heating seasons are optional.
Item
Symbol
Rated heatling
Prated,h
capacity
Declared heating capacity for part load at indoor temperature
20 °C
and outdoor temperature Tj
Item
symbol
Tj = -7℃
Pdh
Tj = 2℃
Pdh
Tj = 7℃
Pdh
Tj = 12℃
Pdh
Tbiv = bivalent
Pdh
temperature
TOL = operating limit
Pdh
For air-to-water heat
pumps: Tj = – 15 °C
Pdh
(if TOL < – 20 °C)
Bivalent
Tbiv
temperature
Degradation
co-efficient heat
Cdh
pumps (**)
Power consumption in modes other than 'active mode'
Off mode
Poff
Thermostat-off
PTO
mode
Crankcase heater
PCK
mode
Capacity control
Sound power
level,indoor/outdoor
LWA
measured
Emissions of
nitrogen oxides (if
NOx (**)
applicable)
GWP of the
refrigerant
SALVADOR ESCODA SA
NÁPOLES 249 P1
Contact details
08013 BARCELONA (SPAIN)
+34 93 446 27 80
Information requirements for heat pumps
Value
Unit
Seasonal space heating
9,5
kW
energy efficiency
value
unit
8,420
kW
Tj = -7℃
5,320
kW
Tj = 2℃
3,165
kW
Tj = 7℃
1,963
kW
Tj = 12℃
Tbiv = bivalent
8,420
kW
temperature
8,549
kW
TOL = operating limit
For air-to-water heat
x,x
kW
pumps: Tj = – 15 °C
(if TOL < – 20 °C)
For water-to-air heat
-7
°C
pumps: Operation
limit temperature
x,x
Back-up heating
0,015
kW
capacity (*)
0,020
kW
Type of energy input
0,000
kW
Standby mode
Other items
For air-to-air heat pumps:
air flow
variable
rate, outdoor
measured
For water/brine-to-air
67/74
dB
heat pumps: Rated
brine or water flow
mg/kWh
rate, outdoor side heat
x
fuel
exchanger
input GCV
kg CO2 eq
675
(100 years)
284
MUCR-42-H11-I
MUER-42-H11-E
Item
Symbol
ηs,h
Declared coefficient of performance or gas utilisation
efficiency/auxiliary
energy factor for part load at given outdoor temperatures Tj
Item
symbol
COPd
COPd
COPd
COPd
COPd
COPd
COPd
Tol
Supplementary heater
elbu
Psb
Value
Unit
157,0
%
value
unit
282,4
%
390,0
%
518,9
%
602,1
%
282,4
%
245,8
%
x,x
%
-10
°C
0,969
kW
0,015
kW
4000
m3/h
x
m3/h

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis