9 Additional Functions
9.1 Switching off the IR receiver
To protect the spotlight against inadvertent op-
eration via the infrared remote control, switch
off the infrared receiver:
1) Call up the menu item
The display will indicate the current setting:
: IR reception switched on
: : IR reception switched off
2) Use the button UP or DOWN to select the
option desired, and then press the button
ENTER to save your selection .
Note: Irrespective of this setting, infrared reception
will always be blocked during the DMX mode .
9.2 Showing the firmware version
To show the version number of the firmware
(operating software of the unit):
1) Call up the menu item
version number will appear on the display for
a few seconds . Then it will disappear again .
2) Use the control buttons to go back to the
operating mode desired .
9.3 Indication of temperature
To indicate the temperature inside the unit:
1) Press the button MENU repeatedly until
(temperature) appears on the display .
2) Press the button ENTER; the temperature (°C)
will be indicated .
3) Use the control buttons to go back to the
operating mode desired .
10 Specifications
Control protocol: . . . . . . . DMX 512
Number of
DMX channels: . . . . . . . . . 1, 4, 5 or 8
Light source: . . . . . . . . . . . 12 × 8 W RGBW LEDs
Beam angle: . . . . . . . . . . . 25°
.
Ambient temperature: . . . . 0 – 40 °C
Power supply: . . . . . . . . . . 230 V/ 50 Hz
Power consumption: . . . . . 100 VA max.
Dimensions: . . . . . . . . . . . 265 × 190 × 130 mm
Weight: . . . . . . . . . . . . . . . 2.1 kg
(version) . The
19