Herunterladen Inhalt Inhalt Diese Seite drucken

Duct Connection; Fan Positioning; Electrical Installation; Setting The Code - Nederman 865 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für 865:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 21
1
Fasten the hose with a hose clip on the connecting
EN
piece inside the drum.
2
Aim the hand control towards the indicator (re-
mote-controlled reel only). Press the UP-button
on the hand control. The indicator shows a fixed
red light. Release the button at the required hose
position.
3
Fit the nozzle.
4 When needed adjust the limit positions for a coiled
and uncoiled hose.

4.2 Duct connection

See
Figure
4. The connection hose supplied with Ex-
haust Hose Reel 865 should be used for connecting
the reel to duct systems and a central fan.
* Hose clip.
NOTE!
The duct must be fitted with hose clips. Do not
drill or fit with screws.

4.3 Fan positioning

A suitable fan can be selected from the Nederman fan
range. To avoid leakage in the ducting system the fan
should be positioned outdoors or as near the duct out-
let in the room as possible.

4.4 Electrical installation

See
Figure
5.
WARNING! Risk of personal injury
• All electrical work must be done by a qualified
electrician according to local regulations.
• All electrical connections should be checked
to ensure they are tight, prior to applying
power.
• Connect the reel to the power supply by joining the
incoming cable to the connection block in the reel's
receiver.
• After installation check that the functions for un-
coiling and coiling the hose correspond to the press
button arrows on the hand control. If not, recon-
nect the cable from the hand control correctly on
the connection block.
Cable recommendation for the hand control: 3 x 0.75
2
mm
, to be connected according to the wiring dia-
gram.
The reel is factory set for the voltage supply of
230/240 V AC.

4.5 Setting the code

Only for a remote-controlled hose reel.
To allow the use of a number of reels in one location,
the reel must be coded.
14
Exhaust Hose Reel 865
NOTE!
Each reel must have its own code. At delivery,
code C has been set (see figure). To set another
code:
1
Make sure the reel is connected to the power sup-
ply.
2
Open the hand control and set one of 8 possible
codes.
3
Put the hand control together. Aim it against the
reel's indicator and push the SET- button (minim-
um 7 s). The indicator verifies by green flashing
light for approximately 2 s. Using the enclosed la-
bels (A B C), mark the hand control and the reel
with the same code letter.
NOTE!
If more than 8 reels are to be used in the same
room, reels with the same code should be
placed at least 10 m from each other to reduce
the risk of interference.
4.6 Adjusting the limit positions for the
coiled and uncoiled hose.
When delivered Exhaust Hose Reel 865 has no limit
positions adjusted for the hose mounted on the reel.
NOTE!
Both limit positions must be adjusted, always
the upper at first, then the lower.

4.6.1 Adjusting the upper limit position

1
Push the up-button on the hand control. Let the
hose be moved to the required upper position. Re-
lease the button.
2
Push the up-and-down button at the same time.
The indicator is flashing green (8x) for a short
time. The limit position has now been adjusted.

4.6.2 Adjusting the lower limit position

1
Push the down button on the hand control. Let the
hose be moved to the required lower position. Re-
lease the button.
2
Push the up-and-down button at the same time.
The indicator is flashing green (5x) for a short
time. The limit position has now been adjusted.
4.6.3 When new limit position settings are
needed
When needed, the limit positions can be adjusted
again. A reset of the limit positions must then be done
in the following way.
• Push the up-and-down buttons on the hand control
at the same time (approx. 15 - 20 s) until the indicat-
or has a fixed red light (2 s).

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis