Herunterladen Inhalt Inhalt Diese Seite drucken

Parkside PBSA 12 E4 Originalbetriebsanleitung Seite 24

Vorschau ausblenden Andere Handbücher für PBSA 12 E4:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
GB
tool may come into contact with
hidden wiring. Contact with a live
wire can also cause a charge in metal
parts of the appliance and result in an
electric shock.
b) Hold the device by the insulated
gripping surfaces when per-
forming work in which the cut-
ting tool may come into contact
with hidden wiring or its own
cord. If the screw were to come into
contact with a live electrical cable,
metal parts of the appliance could
also become live and cause an electric
shock.
c) Do not use any accessories that
are not recommended by PARK-
SIDE. This can result in electric shock
or fire.
8) SAFETY INFORMATION FOR
USING LONG DRILLS
a) Do not work at a speed higher
than the maximum permissible
speed for the drill. Higher speeds
can cause the drill to bend slightly
when rotating freely without contact
with the workpiece and can also cause
injury.
b) Always begin drilling at a low
speed and when the drill is in
contact with the workpiece.
Higher speeds can cause the drill to
bend slightly when rotating freely with-
out contact with the workpiece and can
also cause injury.
c) Do not apply excessive pressure
to the drill. Only apply pressure
lengthwise along the drill. Drills
can bend and break or cause a loss in
control, thus resulting in injuries.
24
9) RESIDUAL RISKS
Even if properly operating and handling
this electric tool, some residual risks will
remain. Due to its construction and build,
this electric tool may present the following
hazards:
a) Cuts
b) Ear damage if working without ear pro-
tection.
c) Damage to your health caused by
swinging your hands and arms when
operating the appliance for longer pe-
riods of time or if the unit is not held or
maintained properly.
Warning! During operation, this
electric tool generates an electro-
magnetic field which, under certain
circumstances, may impair the
functionality of active or passive
medical implants. To reduce the risk
of serious or lethal injuries, we rec-
ommend that persons with medical
implants consult their doctor and
the manufacturer of their medical
implant before operating the ma-
chine.
Observe the safety informa-
tion and notes on charging
and proper use as shown in
the instruction manual for
your battery and charger
from the X 12 V TEAM series.
A detailed description of the
charging process and further
information can be found in
the separate operating in-
structions.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis