2
Product Information
2.1
Declaration of conformity
The design and operating characteristics of this product comply with the
European and national requirements.
The CE marking declares that the product complies with all the
applicable EU legislation, which is stipulated by attaching this
marking.
The complete text of the Declaration of Conformity is available on the
Internet: www.bosch-industrial.com.
2.2
Technical data wired room controller
Power infeed
Permissible ambient temperature
Permissible relative humidity
Table 2 Technical data wired room controller
2.3
Specifications of remote control
Power infeed
Signal range
Permissible ambient temperature
Table 3 Specifications of remote control
2.4
Operating temperature range
Room temperature
Cooling
16 ... 32 °C
Heating
0 ... 30 °C
Dehumidifying
10... 32 °C
Table 4
The built-in protection device may prevent the appliance from operating
at temperatures outside the above range.
If the humidity is more 80 %, condensation may form at the air
outlet. To avoid this, set the fan to a high performance.
Climate 5000i M – 6721849823 (2022/11)
DC 12V
−5 °C... 43 °C
40...90 %
2 AAA batteries
8 m
16... 30 °C
Outside temperature
-15... 50 °C
-15... 24 °C
0... 50 °C
3
Operation
3.1
Indoor unit overview
Key to Fig. 1:
[1]
Air inlet
[2]
Electric control box
[3]
Air filter
[4]
Air Outlet
3.2
Indoor unit display
Key to Fig. 2:
[1]
Manual operation
[2]
Status indicator
[3]
Timer indicator
[4]
Pre-heating and defrosting indicator
[5]
Alarm indicator
[6]
Infrared signal receiver
[7]
LED indicator
The operating modes can be selected in the sequence automatic mode,
cooling mode and shutdown via the Manual operation key.
Manual button
Operating
Display
Mode
Automatic
Operation indicator
mode
on
Manual cooling
Status indicator
mode
flashes
Shutting-down All indicators off
Table 5 Indications on the display unit
3.3
Overview wired room controllers
Keys of the wired room controller
Key to figure 3:
[1]
Receiver for infrared remote control
[2]
Display of the wired room controller
[3]
Keys of the wired room controller
Key
Function
K
Switch on/off.
M
Set operating mode.
DAYOFF Day off/deletion.
. /
Adjust up/down setting.
Confirm choice.
TIMER
Set timer.
Fan step
d
Navigate back.
No function.
FUNC.
Set function.
COPY
Copy/adopt data.
Table 6 Keys of the wired room controller
Product Information
Display output
Cooling and heating modes:
Set temperature
Fan only mode: Indoor ambient
temperature
The system automatically
switches to automatic mode after
30 minutes of forced cooling.
The remote control is deactivated
during forced cooling.
If the display is switched off, the
indoor unit switches off and the
remote control is reactivated.
51