Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connection; Connection In Four-Wire And Six-Wire Configurations - HBM PW15AH Montageanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Electrical connection

5
Electrical connection
The following can be connected for measurement signal conditioning:
S Carrier-frequency amplifiers
S DC voltage amplifiers
that are designed for strain gage measurement systems.
5.1

Connection in four-wire and six-wire configurations

When load cells with a six-wire configuration are connected to amplifiers with a
four-wire configuration, the sense leads of the load cells must be connected to
the corresponding supply leads: Marking (+) with (+) and marking (-) with (-).
6-wire cable connection (available lengths: 3 m; 6 m)
Schematic diagram of a Pancon connector (CE100F26-6), 6-pin
12
Shield (yellow) = cable shield connected to load
cell body
Plug-in contact 1 (white) = measurement signal (+)
Plug-in contact 2 (red) = measurement signal (-)
Plug-in contact 3 (black) = excitation voltage (-)
Plug-in contact 4 (blue) = excitation voltage (+)
Plug-in contact 5 (green) = sense line (+)
Plug-in contact 6 (gray) = sense line (-)
Blue marking
A02435_02_Y00_00 HBM: public
PW15AH

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis