1.4.1.4 Later activation of the radio encryption
The AES encryption can also be activated later. It can be activated as follows:
a) The encryption can be activated by pressing the push-button.
Press the push-button until you change to the display loop "6" (module loop). Then change with a
brief keystroke to the 3rd item "AES off" (see picture).
In order to start the editing mode you afterwards must press the push-button
once again for 2-3 seconds. As an aid, after 2 seconds the "editing pen" will be
displayed bottom left in the LCD. As soon as it appears you have to let go of
the button. Now the display shows "AES on" (see picture).
b) The encryption can also be activated using the software "Device Monitor". This software can be ordered separately as an
option. The encryption can only be deactivated using the software "Device Monitor".
1.4.2 LoRaWAN interface
The LoRaWAN interface transmits meter data (absolute values).

1.4.2.1 Technical data

Radio characteristics
Frequency 868 MHz
Output power 14 dBm
Receiver sensitivity -135 dBm
LoRaWAN characteristics
Device class
LoRa version
Activation
Data rate
*OTAA
= Over-the-air activation
** ABP
= Activation by personalization
1.4.2.2 LoRa module configuration
The module can be configurated by using the Device Monitors or the OTC App.
Parameter
Power mode
Configuration Lock
Synchronize meter time
Activation type
EcoMode
Transmit interval *[Min.]
Message format**
Pulse input selection
Page 48 of 58
1080619050 / MH 4310 INT5
Frequency 868 MHz
Output power 14 dBm
Receiver sensitivity -135 dBm
Class A, Bi-directional
1.0.2 Rev B
OTAA* or ABP*
DR0-DR5 (250 bit/s-5470 bit/s)
Possible settings
Active
Inactive
Open
Locked
on
off
OTAA
ABP
off
6 years
10 years
5 ... 1440
Standard
Sensus
Compact
JSON
Scheduled - daily redundant
Scheduled - extended
Combined heat/cooling
Choice between 0-3 pulse inputs
Stand: 2021_07_05 V 0001
Factory setting
Inactive
Open
off
OTAA
EcoMode 10 years
60
Standard
0