Replacing the safety filter bag
DANGER
Danger from dust that is harmful to your
health
Respiratory sicknesses through inhalation
of dust.
Accumulated dust must be transported in
dust-proof containers. Do not transfer the
contents. The dust bag may only be dis-
posed of by qualified staff.
1. Secure the device with the parking
brakes.
2. Remove the suction hose.
3. Close the suction connection on the dirt
receptacle (see chapter Closing the
suction connection).
Illustration C
4. Pull the bow handle up.
The dirt receptacle is unlocked and low-
ered.
Illustration D
5. Pull the dirt receptacle out of the device
by the bow handle.
Illustration J
6. Fold up the safety filter bag.
Illustration K
7. Peel off the protective film.
8. Close the safety filter bag with the self-
adhesive flap.
9. Pull the safety filter bag out towards the
rear.
Illustration L
10.Seal the suction connection opening of
the safety filter bag tightly with the cover.
Illustration M
11.Close the safety filter bag tightly with the
attached cable tie.
12.Remove the safety filter bag from the
dirt receptacle.
13.Clean the interior of the dirt receptacle
with a moist cloth.
14.Dispose of the used safety filter bag in
dust-tight bag in accordance with statu-
tory regulations.
Illustration F
15.Fit the new safety filter bag.
Illustration G
16.Fold the edge of the safety filter bag out
over the edge of the dirt receptacle.
WARNING
Improper handling when locking the dirt
receptacle
Risk of crushing
Under no circumstances should you hold
your hands between the dirt receptacle and
filter ring or allow them to come close to the
lifting mechanism while locking it.
Lock the dirt receptacle by operating the
bow handle with both hands.
Illustration H
ATTENTION
Static charge of the dirt receptacle
Ignition of dusts
Make sure that the grounding on the chas-
sis is in contact with the dirt receptacle.
17.Fit the dirt receptacle and lock it with the
bow handle.
Troubleshooting guide
DANGER
Unintentional start-up of the device /
electric shock
Unintentional start-up of the suction motor
can cause injuries. Voltage present on
electrical parts can cause an electric shock.
Switch off the device and unplug the mains
plug before performing any work on the de-
vice.
Have all checks and work on electrical
parts performed by an qualified technician.
Note
The device must be switched off immedi-
ately in the event of a malfunction. The mal-
function must be eliminated before
switching the device on again.
If the malfunction cannot be corrected, the
device must be checked by the Customer
Service department.
Suction turbine does not start up
1. Check the socket and the power supply
fuse.
2. Check the mains cable and the mains
plug of the device.
3. Switch the device on.
Suction power decreases
1. Close the unsealed suction connection
(see chapter Closing the suction con-
nection).
English
31