2.4
Hygiene
Damage to health caused by dirty or polluted water.
Operating the cleansing functions with dirty or polluted
water can cause health damage.
> Supply the product with cold drinking water from the
main water system.
> Do NOT connect any waste water, grey water,
industrial water, sea water or other untreated or
semi-treated water.
> The new hose-sets supplied with the appliance are to
be used and old hose-sets should not be reused.
> Activate additional self-cleaning via app if the product
has not been used for two weeks or above.
→ App: Menu – Care – Self-cleaning
2.5
Avoiding product damage
General precautions
> Only use the parts in the installation kit to avoid
malfunctions.
> Only use attachments recommended by Duravit.
Damage through freezing water
Do NOT install and operate the product in rooms where
there is a danger of frost. The room temperature must
not be less than 4 °C (39 °F).
Damage through limescale build-up
In regions with hard water, limescale can build-up.
Limescale can impair the performance of the product.
> Check the water quality in your region. Duravit
recommends the installation of a water softener with
water hardness ≥ 14° dH (2.5 mmol/l).
3.
Requirements at the installation location
The pre-installation is carried out properly. The water
and power supply for the product are installed properly.
> Access the pre-installation data sheet at
qr.duravit.com or www.duravit.com
> Ensure that there is enough floor space to install the
toilet and that the bathroom door will open and close
without obstruction.
> Ensure that the lid will open and close without
obstruction against window frames, shelves and other
bathroom furniture.
8
53978_MI_SensoWash_WWC
4.
Drawings and plans
Position of water and electrical installation
180
IG 1/2"
90
3
1/2"
> Install the water connection and water outlet in the
specified areas.
> Install electrical connection in the specified areas.
5.
Technical Data
Electrical
Rated voltage
61X XXX XX 2 XX XXXX
61X XXX XX 1 XX XXXX
Rated power
Circuit breaker
RCD
Protection degree
Protection class
Cable specification
Water
Cold water
DN 15 (½")
Water pressure
0.07 – 0.75 MPa
(10 – 109 psi)
Water hardness
max. 2.4 mmol/l
(240 ppm)
7
1/8"
90
3
1/2"
220 – 240 V, 50 – 60 Hz
100 – 120 V, 50 – 60 Hz
(US/Taiwan models)
1080 W
I
= 16 A
N
I
= 30 mA
N
IP X4
I
Cross section
1 – 2.5 mm2
(17 – 14 AWG)