PME-MP55DP
6.4 Diagnosis
The MP55DP module makes a device diagnosis available as an external
diagnosis which can be released via the parameter assignment diagram.
The external diagnosis is 4 bytes long. The first byte contains the identification
character for the version number. The second byte contains the identification
character for device diagnosis. In the third and fourth bytes one bit each is
reserved for various fault causes.
Octet
Bits
Value
0
0−7
c1
1
0−7
4
2
0
0
1
2
1
2
2
0
1
2
3
0
1
2
4
0
1
2
5
0
1
2
6
0
1
2
7
3
0−3
3
4
0
1
3
5
0
1
3
6
0
1
3
7
0
1
4
0
0
1
4
1−7
Tab 6.8:
Contents of diagnosis
A0582-3.1 de/en/fr
Meaning
version 1
length of device diagnosis is 4 bytes in total
hardware overflow
ADC overflow
gross overflow
net overflow
analogue output overflow
maximum overflow
minimum overflow
scaling of input characteristics defective
scaling of output characteristics defective
nominal value exceeded
works calibration defective
transducer error
res
res
res
37
HBM