4.8.7 Reset to factory settings
Resets all settings made by the user to the pre-set
factory settings.
Press and hold the ENTER key for five seconds.
INFO display flashes.
Press
or
to select the Fr display. The symbol
flashes.
Press the ENTER key. Display N (= no) flashes.
Press
or
to select the Y display. The symbol
flashes.
Press the ENTER key. All values are reset to
factory settings.
Set the time and date.
4.8.8 Increasing the set point
The room heating device is delivered from the factory
with an adjustable temperature range of 7 °C to 26 °C.
The upper limit value can be increased (max. 32 °C) or
lowered as required.
Press and hold the MENU key, the BACK key and
the ENTER key for five seconds.
SP display flashes.
Press the ENTER key. °C display flashes.
Press the ENTER key. Display 26 (limit value set at
the factory) flashes.
EN-22
Press
or
limit value.
Press the ENTER key.
Confirm the BACK key to return to the standard
display.
4.8.9 Service information
NOTE
This information is exclusively for service technicians.
The following information can be displayed:
UI number Service number display
CC number: Service number electronics
ID number: Service number heating device
Press and hold the ENTER key for five seconds.
INFO display flashes.
Press
or
Confirm the BACK key twice to return to the
standard display.
NOTE
Display id is a code with 12 digits.
The first 4 digits are shown on level 1.
Press or to select the next level (2, 3).
5. Overload protector
For your safety, the heating device is equipped with
an overload protector. If the air circulation is inter-
rupted (e.g. due to the air grille being covered or
closed), the device switches off automatically.
In this case, the power supply to the heating device
should be disconnected for a few minutes (discon-
nect the plug, switch off the fuse) to allow the device
to cool down sufficiently.
Before recommissioning the device, remove the rea-
sons for the overload protector being triggered.
6. Maintenance
The device must be disconnected from the mains and
allowed to cool down before maintenance.
Clean the outside of the device using a soft, damp
cloth. Do not use scouring powder or furniture polish
as this may damage the surface.
Dust which gathers inside the device can be removed
from the outside using a vacuum cleaner.
2208/F
PLX 050E - PLX 300E
to increase or lower the desired
to select the display Ui, CC or id.
www.dimplex.eu