TIPS ABOUT AUTO MODE
In the AUTO mode, the temperature setting and mode are automatically
selected according to the room temperature when the unit is turned on.
Modes and Temperature Settings for Models AH-AP18DR/AH-AP24DR
Room temp. at opera-
tion start-up
Below 24°C
24°C-26°C
26°C-28°C
Above 28°C
Modes and Temperature Settings for Models AY-AP18DR/AY-AP24DR
Room temp. at opera-
tion start-up
Below 21°C
21°C-24°C
24°C-26°C
26°C-28°C
Above 28°C
TIPS ABOUT FAN SPEED LAMP
During operation, the FAN SPEED Lamp will light up in 3 levels (2 levels
for DRY mode) on the indicator panel of the unit to indicate the fan
speed.
When fan speed is set to AUTO
The AUTO FAN SPEED Lamp
will light up.
To turn off the FAN SPEED Lamp, press
the DISPLAY button.
The PLASMACLUSTER Lamp will also go off.
Automatic Operation
Mode
Thermostat Setting
DRY
Room Temp. at start-up
COOL
COOL
COOL
Automatic Operation
Mode
Thermostat Setting
HEAT
DRY
Room Temp. at start-up
COOL
COOL
COOL
When fan speed is set to manual
DISPLAY MODE
E-9
24°C
25°C
26°C
23°C
24°C
25°C
26°C
Soft speed
Low speed
High speed
1h
FAN
SWING CANCEL