8
TECHNISCHE DATEN ECODESIGN
ECODESIGN REQUIREMENTS FOR SOLID FUEL BOILERS
ACCORDING TO COMMISSION REGULATION (EU) 2015/1185
AND ECOLABEL REQUIREMENTS FOR SOLID FUEL BOILERS
ACCORDING TO COMMISSION REGULATION (EU) 2015/1186
ITALIANA CAMINI – DIDA2 PLUS, TEN2 PLUS
Indirect heating functionality: NO
Direct heat output: 13,0 kW (space heat output)
Indirect heat output: ---- kW (water heat output)
Preferred
Other
Fuel
fuel (only
suitable
one):
fuel(s):
Log wood, moisture
no
content ≤ 25 %
Compressed wood
with moisture content
yes
yes
< 12 %
Other woody biomass
no
Non-woody biomass
no
Anthracite and dry
no
steam coal
Hard coke
no
Low temperature coke
no
Bituminous coal
no
Lignite briquettes
no
Peat briquettes
no
Blended fossil fuel
no
briquettes
Other fossil fuel
no
Blended biomass and
no
fossil fuel briquettes
Other blend of
no
biomass and solid fuel
Characteristics when operating with the preferred fuel only:
Seasonal space heating energy efficiency ηs [%]: 86,1
Energy efficiency index EEI: 127
Item
Symbol
Value
Heat output
Nominal heat output
P
13,0
nom
Minimum heat output
P
5,2
min
(indicative)
Auxiliary electricity consumption
At nominal heat output
el
0,165
max
At minimum heat output
el
0,100
min
0,002
In standby mode
el
SB
Permanent pilot flame power requirement
Pilot flame power
N.A.
requirement (if
P
pilot
applicable)
Contact details
Name and address of the manufacturer or its authorized representative.
Tel. +39 02 937621
Manufacturer: EDILKAMIN SPA
www.edilkamin.it
Via Mascagni 7
mail@edilkamin.it
20020 Lainate (MI) – ITALY
BENUTZER/INSTALLATEUR
Space heating emissions at
nominal heat output(*)
η
s
PM
OGC
CO
NOx
[%]:
3
mg/m
at 13%O
2
no
86,1
13
2
18
109
no
no
no
no
no
no
no
no
no
no
no
no
Energy efficiency class: A+
Unit
Item
Symbol
Useful efficiency (NCV as received)
Useful efficiency at
kW
η
nominal heat output
Useful efficiency at
kW
minimum heat output
(indicative)
Type of heat output/room temperature control
(select one)
single stage heat output, no room
kW
temperature control
two or more manual stages, no
kW
room temperature control
with mechanic thermostat room
kW
temperature control
with electronic room temperature
control
with electronic room temperature
control plus day timer
with electronic room temperature
kW
control plus week timer
Other control options (multiple selections
possible)
room temperature control, with
presence detection
room temperature control, with open
window detection
with distance control option
Space heating emissions at
minimum heat output(*)(**)
PM
OGC
CO
NOx
3
mg/m
at 13%O
2
18
27
166
74
Value
Unit
90,3
%
th,nom
η
88,8
%
th,min
NO
NO
NO
NO
NO
YES
NO
NO
YES
®