The meter can be connected to a control gun or
installed directly in the distribution line pipe.
It is recommendable to install a cut-off valve
before the meter to facilitate its maintenance or
repair.
The meter has a 1"BSP connection at the inlet
and outlet (366760).
The supplied 1"BSP F-F bushing enables several
combinations of threads (366761).
The meter requires two 1.5 V batteries and size
AAA as the power supply source. See "battery"
section.
Display LCD
The "LCD" of the METER features two numerical
registers and various indications displayed to the
user only when the applicable function so
requires.
1. Partial register (5 figures with moving comma
FROM 0.1 to 99999) indicating the volume
dispensed since the reset button was last
pressed.
2. Indication of battery charge.
3. Indication of calibration mode.
4. Totals register (6 figures with moving comma
FROM 0.1 to 999999), that can indicate two
types of Total:
4.1. General Total that cannot be reset
(TOTAL).
4.2. Resettable total (Reset TOTAL).
5. Indication of total multiplication factor (x10 /
x100).
6. Indication of type of total, (TOTAL / Reset
TOTAL).
836 828 R. 01/16
2
SAMOA Industrial, S.A. · Pol. Ind. Porceyo, I-14 · Camino del Fontán, 831 · 33392 - Gijón - Spain · Tel.: +34 985 381 488 · www.samoaindustrial.com
Installation
Main components:
1. LCD display
2. RESET key
3. CAL key
4. F-F bushing (366761)
NOTE: In order to improve the life of the
turbine, it is recommended to fit a strainer
before the meter itself.
Operating mode
Description
7. Indication of unit of measurement of Totals:
L=Litres
8. Indication of Flow Rate mode.
9. Indication of unit of measurement of Partial:
=Quarts
Q
TS
L=Litres
1
2
3
1
2
3
4
=Gallons
G
AL
=Pints
P
TS
=Gallons
G
AL
4
5
9
8
7
6