SUBMERSIBLE PUMP

1. Safety measures

Carefully read the operating instructions before
assembling and starting. The appliance must not be
used by persons who are not thoroughly acquainted
with the instructions handbook (operating instructions).
Children and persons under the age of 16 cannot use
the pump and must be kept well away from the
appliance when it is connected. The user is liable
towards third parties in the area where the appliance is
in operation.
ENGLISH (Original instructions)
While
persons must not be in the liquid to
be pumped.
The pump may be connected only by
means of a safety switch for fault currents, with
a rated opening current up to 30 mA and a
socket with an earth contact installed in
conformity with the regulations.
Protection: at least 10 Amps.
Operation in swimming pools and garden ponds is
admitted.
For other operation, the provisions in conformity
with the standard VDE 0100 part 702 must be
CAUTION: Before checking, connect the pump
and the system with no voltage!
Replacing the line connecting up with the mains
requires using special tools and therefore may be
done only by the manufacturer or its service
engineers.
The pump may operate only with a pipe connecting
the appliance (extension) that is no lighter than a
rubber hose mod. H07 RNF in conformity with the
DIN 57282 or DIN 57245 standard.
(For your safety)
The voltage (230 Volts alternating current) indicated
on the pump's rating plate must correspond
to the available mains voltage.
Before starting it is necessary to make sure by having
a check made by qualified personnel that there are the
necessary electrical protection measures.
• Earth connection.
• Earthed neutral.
• The safety switch for fault currents corresponds to
the safety regulations of the electricity board and
functions perfectly.
• Plug connections must be protected from water. If
there is a risk of flooding, plug connections must be
placed somewhere safe.
• Definitely avoid pumping aggressive liquids and
abrasive products.
In the event of the pump failing, repair work may only
be carried out by the repair workshops of the technical
service. Only genuine spare parts must be used.
It is notified that in conformity with the law on product
liability
we cannot be held responsible
for the damage caused by our appliance:
a) because of improper repairs not carried out by the
personnel of the assistance points authorized by us;
b) or if GENUINE SPARE PARTS are not used to
replace parts;