Herunterladen Inhalt Inhalt Diese Seite drucken

Zibro Arabella Gebrauchsanweisung Seite 61

Vorschau ausblenden Andere Handbücher für Arabella:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
F. TEchnicAL sERVicE, ORiginAL sPARE PARTs
Before leaving the factor�, each stove has been carefull� tested and commissioned.
An� repairs or commissioning that ma� become necessar� during or after installa-
tion must be carried out b� heating engineers authorized b� Zibro. Original factor�
spare parts can be obtained onl� and exclusivel� from our Technical Servicing Cen-
ters and authorized points of sale.
When contacting �our dealer, the Technical Service Centre or the authorized hea-
ting engineer, first make sure to be able to specif� the model and serial number at
their first request.
Onl� use original Zibro spare parts. Using non original Zibro spare parts will lead to
nullification of the warrant�.
g. TROUBLE shOOTing
Problem
problems during start-up
condensation forms
smoke leaks out of the stove
Glass gets too dirt�
Possible cause
Wood size is too big
Wood is too humid
not enough draught in the chim-
ne�
there is not enough fresh air sup-
plied to the room
too much draught
Chimne� flue section is too large
Chimne� flue is not insulated well
combustion is too slow
Chimne� flue is not insulated well
unfavourable weather conditions
(too strong wind)
unfavourable
weather
conditi-
ons, (too little wind, mist�/fogg�
weather conditions)
Wood is too humid
charging door seal is damaged or
worn out
not enough draught in the chim-
ne�
Wood is too humid
combustion is too slow
Fuel is of poor qualit�
Possible solution
Use ver� dr� small wood sticks be-
fore larger size wood
Use seasoned (dr� enough) wood
turn all settings to maximum ope-
ning and check that the chimne�
flue is not obstructed.
Check if chimne� shut off damper
is full� opened
Immediatel� provide an aeration
grid, please refer to an authorized,
specialised heating engineer.
Primar� air inlet to minimum
Reduce the chimne� flue section
using thermall� insulated pipes
(needs to be done b� specialised
heating engineer, such as for
example a chimne� sweeper or
chimne� installer)
Line the chimne� flue with insula-
ting material (onl� b� authorized
professional)
open air parameters to increase fire
and temperature of outlet fumes
Line the chimne� flue with insula-
ting material (onl� b� authorized
professional)
Chimne� pot is not wind protected,
(re-)place it.
this is normal, operating the stove
at these weather conditions should
be avoided.
use seasoned, dried wood
have charging door seal replaced
b� authorized technician
turn all settings to maximum ope-
ning and check that the chimne�
flue is not obstructed (needs to be
done b� specialised heating engi-
neer, such as for example a chim-
ne� sweeper)
use seasoned, dried wood
open air parameters to increase fire
and temperature of outlet fumes
use fuel as described in paragraph
d.3
4
61

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis