Stove switches off.
Alarm displayed is
"AlAr dEp"
Stove switches off.
Alarm displayed is
"AlAr dEp"
Stove switches off.
Alarm displayed is
"AlAr Sic"
Fumes extractor is
damaged
Possible obstructions of
the combustion air inlet
tube
Pressure sensor/switch
is broken
Electronic circuit board
is broken
Excessive chimney
length
Unfavourable weather
conditions
Stove is overheated
Stove is overheated
The room air recircula-
tion fan is broken
Temporary power
failure
Thermostat is broken
Air filter obstructed
Electronic circuit board
is broken
Wood pellets can burn thanks to the
chimney flue having natural draught.
Have fan replaced immediately (cod.
Com0259) as it can be bad for your
health. By authorized Zibro technician
only
Clean the fresh air inlet tube. (see
picture 5 in chapter D.7.)
Replaced the pressure switch code
COM0233. By authorized Zibro techni-
cian only
Replace the electric circuit board code
COM0231. By authorized Zibro techni-
cian only
Call an expert chimney expert to
verify if the chimney is according to
the law.
Call authorized Zibro technician to
verify whether chimney is suitable for
the stove.
When there is a very strong wind a
negative depression to the chimney
can occur. Verify and start the stove
again.
Too high room temperature. Open
doors to other rooms. If the problem
continues call authorized Zibro tech-
nician
Let the stove cool down and stoke it
again. If the problem continues call
authorized Zibro technician
Replace the fan, code COM0237. By
authorized Zibro technician only
A voltage failure during the functio-
ning of the stove causes an overhe-
ating of the internal stove. Let the
stove cool down and stoke it again.
Replace the thermostat, code
COM0238. By authorized Zibro techni-
cian only
Clean the filter (see paragraph F.3.2)
Replace the electronic circuit board.
Code COM0231 By authorized Zibro
technician only