Original operating manual
Back pressure regulators UV 3.9 ATEX
If a pressure-regulating valve has to be dismantled:
The following must be observed at all costs: First release the tension fully on the spring by
turning the setting screw on the spring module anticlockwise. DWhen doing so, be sure to
danger of
fatalities
follow the notes in section Initial start-up [} 14]!
Then either seal off the two shut-off valves installed before and after the fitting in accordance
with the MANKENBERG installation recommendation and vent the pressure-regulating valve
or remove the pressure from the section of the system and then remove the fitting from the
pipeline.
If a fitting is removed from a system with a toxic medium and is taken out of the plant:
it must be properly decontaminated before repair.
caution

5 Transport and storage

A fitting must be handled, transported and stored with care:
» The fitting must be transported and stored in its protective packaging until it is installed.
The fitting has moving internal parts.
Even packaged fittings should be transported smoothly without any shocks.
caution
In the case of a fitting that can no longer be transported by hand, the lifting gear must be
attached to a suitable position on the housing (branches).
Under no circumstances may the lifting gear be affixed to any attachments (adjusting
caution
screw, handwheel or accessories).
» When the fitting is stored prior to installation, it should be kept in closed rooms and protected against
harmful influences such as dirt, moisture and frost.
» In special cases, the fitting is supplied free of oil, grease or silicone and is marked accordingly. A fitting such
as this must not come into contact with oil/grease/silicone during storage and handling (particularly when
subsequently unpacked).
» A MANKENBERG fitting generally has functional and/or sealing parts made of elastomer materials. These
cannot be stored for an unlimited period.
ISO 2230 describes the storage conditions for elastomers in detail and specifies the
permissible storage period.
Functional and sealing parts must be replaced well before the storage period expires.
note
They are available from MANKENBERG as a "service set". See also Section Troubleshooting
help [} 17].
MANKENBERG fittings of small and medium nominal diameters are largely made of stainless
steel (high-alloy CrNiMo steel).
If, under exceptional circumstances, fittings are stored in a unpacked state, they must be
note
protected against ferritic dust to avoid corrosion.
UV 3.9 ATEX-4.X.222 Issue 18.07.2022
8
www.mankenberg.com