Operating Instructions smartBOX
Flow Rate Max. (ml/min)
Waiting Time to Suck back Wait Time between forward and backward rotation
Suck back Amount
Please note that the Suck Back Amount is always sub-
tracted from the dispensing quantity .
Example: Dispense Amount
Suck back Amount Unit
Suck back Speed
Suck back Speed Setting
Unit
Dispense Amount Display Valid:
Dispense Amount Decision Valid:
Decision Threshold
Flow Rate Calibration
Highest acceptable flowrate for the selected eco-PEN
model in this program as limit for high viscosity material .
(suck back) of the eco-PEN
Quantity of eco-PEN suck back
Suck Back Amount
Real Dispense Quantity
Unit for the eco-PEN suck back in [µl], [ml] or [g]
Rotation speed for the backward rotation of eco-PEN
Unit for eco-PEN suck back in [ml/min] or [%]
The dispensed amount (measured via the
eco-PEN rotational encoder steps) gets shown in
the display of the teaching pendant after the
dispensing is finshed .
Invalid: Dispensed amount does not show up .
The dispensed amount (measured via eco-PEN
encoder steps) is checked for being in the
acceptable range .
A status message (OK/NOK) will be shown on the
smartBOX display after dispensing .
Invalid: No tolerance check is performed
Tolerance (+- [%]) for dispense amount measurement via
the eco-PEN Encoder steps
Starts the calibration procedure of the flowrate either by
weight or volume .
100 µL
10 µL
90 µL
43
VIEWEG
EN