WATER CIRCUIT CONNEC-
TION
Connect the feed hose to
the mains (fig. 4A) and to
the hosetail on the cleaner
(fig. 4B).
Check that the pressure and
quantity of the water supplied
by the mains are sufficient for
the cleaner to work properly: 2
to 8 BAR (29 to 116 PSI).
Maximum temperature of fee-
ding water 50°C (122°F).
Connect the high pressure
hose to the cleaner (fig. 4C)
and to the lance (fig. 5).
!
Danger
The cleaner must operate
with clean water. Dirty or
sandy water, corrosive che-
micals and solvents can
cause severe damage to
the cleaner.
!
Danger
Never suck up liquids contai-
ning solvents or acids in the
pure state, for example petrol,
paint solvents or diesel. The
spray mist from the lance is
highly inflammable, explosive
and poisonous.
Failure to respect the above
absolves the manufacturer of
all liability and represents ne-
gligent use of the product.
Information
Respect the instructions provided by the water
utility company.
Current regulations specify that the appliance may not be con-
nected to the drinking water supply unless a suitable system
separator is fitted.
Use a suitable EN 12729 type BA system separator.
Water passing through a system separator is no longer classi-
fied as drinking water.
!
Warning
Do not connect the machine to a drinking water container.
English
C
B
A
FIG. 4
FIG. 5
- 21 -
ELECTRICAL CONNECTION
Connection of the cleaner to the mains must be carried out by
skilled technicians able to ensure that all regulations in force
are complied with use in respect of current standards and
legislation.
Ensure that the mains voltage available is the same as the vol-
tage at which the cleaner is supposed to work; this is indicated
on the identification plate.
!
Danger
- The electric cable must be protected from accidental cru-
shing.
- Do not use the machine if the supply cable is damaged.
- The use of any electric appliance requires the respect of
some basic rules:
• Do not touch the appliance with wet or damp hands or feet.
• Do not use the appliance bare-footed or with unsuitable
clothing.
• Do not pull the supply cable or the appliance itself in order
to disconnect the plug from the electric supply.
cleaners rated at less than 3 kW fitted with plug).
As for the protection against electric shock, the H.P.cleaner
belongs to CLASS I.
Failure to observe the above warning frees the manufac-
turer from all responsibility and constitutes negligent use
of the product.
(For water