Technical data
Electrical data
Mains voltage
input
Grid frequency
Mains current
Mains fuse protection
Efficiency
Effective power
Power input (stand-by)
Protection class
Maximum permitted mains impedance at the inter-
face (PCC) to the public grid
EMC device class
Marks of conformity
Standards
IEC 60068-2-6
IEC 60068-2-29
EN 60335-1
EN 62233
Electrical data -
Nominal output voltage
output
Output voltage range
Output current
Acctiva Smart 25 A
Output current
Acctiva Professional 35 A
Battery return current
*)
35 A in Power Supply mode
Battery data
6 V / 12 V / 24 V DC
Sine oscillations (10 - 150 Hz; 1.5 h / axis)
Repetitive shock (25 g / 6 ms / 1000 shocks)
EN 60335-2-29
EMF standard
~ 230 V AC, +/- 15%
50/60 Hz
max. 9 A eff.
max. 16 A
max. 96%
max. 1120 W
max. 2.4 W
I (with ground conduc-
6 V / 12 V / 24 V DC
2 V - 31 V
*)
25 A
at 28.8 V DC
*)
25 A
at 14.4 V DC
*)
25 A
at 7.2 V DC
35 A at 28.8 V DC
35 A at 14.4 V DC
35 A at 7.2 V DC
< 1 mA
3 - 350 Ah
tor)
None
A
CE
85