c) Replacing the UV-C emitter
Perform the following steps:
1 Turn off the air purifier and unplug it from the mains socket.
2 Turn the air purifier upside down (by 180°) and place it
on a soft surface, e.g. a blanket.
Turn the lid on the bottom of the air purifier slightly to the
left (counter-clockwise) to unlock.
3 Take off the lid and pull out the filter.
Pay attention to the orientation (the filter faces the UV-C emitter with a deeper
opening; on the outside you can see two textile strips by which you can pull the filter
out).
We recommend that you check the filter for soiling and clean it, if necessary, at the
same time (see section 8. b.).
4 Let the faulty emitter cool down completely before replacing it. Make sure it is cool
before touching it or pulling it out. Use heat-resistant gloves or a cloth if necessary.
Remove the UV-C emitter and replace it with the one of identical rating (same type,
same configuration, same electrical and optical data).
Do not use force when replacing the emitter.
Never touch the emitter with bare hands. You can use e.g. a clean cloth. Fingerprints
or soiling left on the emitter glass can cause glass turbidity under the action of heat,
thus reducing the strength of UV-C radiation and its disinfection capacity.
Attention!
Never use any other emitter, for example, the one with a higher capacity. This can damage the air purifier
and cause hazardous UV-C radiation exposure.