4. CONFIGURATION OF THE LOCK FOR LEFT HAND OR RIGHT HAND OPENING
If needed, you can reverse the unlocking direction (fig. 3)
1 - Remove the screw (Z mark fig3) from its position.
2 - Screw the screw into the 2nd available screw pitch to reverse the opening mechanism.
The internal button always remains unblocked and turns freely to open or close the lock.
IMPORTANT : Before installing the lock, make sure the bolt in the internal block is in the right position.
If it is not the case: (fig. 4a)
a – Lay the internal block on a flat surface, the 4 rear screws visible.
b – Remove the 4 screws and the plate.
c – Remove the bolt and reverse it (on the left side or on the right side, the drive sheave down)
d – Place the 4 washers on the "nut" parts
e – Screw the plate
(fig. 4b) Right hand assembly
5. POSITIONING THE LOCK
IMPORTANT : Determine the strike to use (flush-mounted or surface-mounted) and mark its position on the frame before
drilling the door.
CAUTION: The bolt is 35 mm taller regarding the side of the lock.
Present the internal block with the handle in vertical position and hold it on the door with an end of the bolt aligned with
the frame where the strike will be installed (see step 7).
Mark the position of the upper mounting hole using the template at the back of 1st page and mark the position of the
lower mounting hole and the hole for the square.
Drill 7 mm holes for the attachment screws and one 9.5 mm hole for the square.
6. FIXING THE LOCK
IMPORTANT : Do not close the door before BEING SURE the code works properly.
The square is planned for 35 to 65 mm thick door.
For lower than 50 mm thick doors, separate a size of 12 mm at the end of the square.
Cut the end of the attachment screws according to the thickness of the door so that with the flanges the screws hold
the lock with three threads
CAUTION: lThe lower attachment screw is longer than the upper screw.
Hold the lock into position, the rear face and the neoprene flanges on the door with the square into
position. Screw all the elements starting by the upper screw.
7. INSTALLING THE STRIKE
First, choose the relevant type of strike for your door and then place the strike on the frame so that it is aligned with the
bolt and mark the corresponding holes.
If you use the surface-mounted strike, only screw it (fig. 7a). Use the supplied parts if necessary.
The flush-mounted strike will require making a small flush-mounting (fig.7b).