CAUTION
Rotating components in the intake and pressure socket area. Risk of injury when reaching into
the sockets.
In particular, observe the following: A unit that has stopped due to overload can start up unex-
pectedly!
Do not reach into the opening of the intake socket or pressure socket while the power plug is
plugged in.
If the sockets are freely accessible during operation, e.g. if no hoses are connected, use a hand
guard to secure the sockets. The hand guard is available as an accessory.
NOTE
If the pump is used for conveying excessively soiled water, the impeller unit will be subject to in-
creased wear and will require earlier replacement.
Thoroughly clean the pond or pool before installing the pump.
Install the pump at a raised level above the bottom of the pond. This reduces intake of muddy
water.
Avoid direct sunlight on unit components that are not submerged, as they may overheat. If
necessary, use a protective cover.
Connect the unit
Connect the pump according to the desired installation variant. (→ Installation variants)
Do not plug the power plug into the socket yet!
Water flow only through the filter housing
B
Water flow through the filter housing and through a satellite filter or skimmer
C
Installing the unit
D
• Place the pump horizontally on a stable, mud-free surface.
• Ensure secure and stable positioning of the pump.
• Only operate the pump when it is fully submerged.
The pull rope allows you to simply pull the pump from the water.
− Fasten the pull rope on the bottom filter casing through the round openings and make a
knot.
16