Spezifikationen
extsensor all show
extsensor all show
extsensor {port_num} {sen_field} value show
extsensor {port_num} {sen_type} label set
"{name}"
extsensor {port_num} {sen_type} label show
extsensor {port_num} type show
extsensor {port_num} {sen_type} {sen_field}
events set {off=0|on=1}
extsensor {port_num} {sen_type} {sen_field}
events show
extsensor {port_num} {sen_type} {sen_field}
events type set
"{EVT_SYSLOG=0,EVT_SNMP=1,EVT_EMAIL=2,E
VT_SMS=3,EVT_GSMEMAIL=4,EVT_BEEPER=5,E
VT_DISPLAY=6,EVT_CONSOLE=7,EVT_MQTT=8}
"
extsensor {port_num} {sen_type} {sen_field}
events type show
extsensor {port_num} {sen_type} {sen_field}
maxval set {num}
extsensor {port_num} {sen_type} {sen_field}
maxval show
extsensor {port_num} {sen_type} {sen_field}
minval set {num}
extsensor {port_num} {sen_type} {sen_field}
minval show
extsensor {port_num} {sen_type} {sen_field} hyst
set {num}
extsensor {port_num} {sen_type} {sen_field} hyst
show
extsensor {port_num} {sen_type} {sen_field}
publish mode set {NONE=0|INTERVAL=1|
DELTA=2|INTERV_DELTA=3}
extsensor {port_num} {sen_type} {sen_field}
publish mode show
extsensor {port_num} {sen_type} {sen_field}
publish mqtt retain set {OFF=0|ON=1}
extsensor {port_num} {sen_type} {sen_field}
publish mqtt retain show
extsensor {port_num} {sen_type} {sen_field}
publish timer set {num_secs}
extsensor {port_num} {sen_type} {sen_field}
publish timer show
extsensor {port_num} {sen_type} {sen_field}
publish delta set {float}
extsensor {port_num} {sen_type} {sen_field}
publish delta show
extsensor {port_num} {sen_type} {sen_field}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} port set {port_num}
extsensor {port_num} {sen_type} {sen_field}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} port show
extsensor {port_num} {sen_type} {sen_field}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} state set {OFF=0|ON=1|
DISABLED=2}
extsensor {port_num} {sen_type} {sen_field}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} state show
extsensor period set {24H=0|12H=1|2H=2|1H=3|
30MIN=4}
extsensor period show
Expert Power Control 8316
show s all values from connected external
sensors
show s all plugged sensors and fields
show s sensor value
sets sensor name to label
show s label of sensor
show s type of sensor
enables sensor events on/off
show s if sensor events are enabled
enables different event types
show s w hat event types are enabled
sets maximum value for sensor
show s maximum value for sensor
sets minimum value for sensor
show s minimum value for sensor
sets hysterese value for sensor
show s hysterese value for sensor
sets publish mode
show s publish mode
sets mqtt retain
show s if mqtt retain set
sets publish time interval
show s publish time interval
sets publish delta value
show s publish delta value
sets Port for Pow er Port Sw itching actions
show s Port for Pow er Port Sw itching actions
sets Port state for Pow er Port Sw itching actions
show s Port state for Pow er Port Sw itching
actions
sets sensor Min/Max measurement period
show s sensor Min/Max measurement period