Spezifikationen
ip6 manual gatew ay show
ip6 manual dns {1..2} set "{ip_address}"
ip6 manual dns {1..2} show
ipacl
ipacl ping enabled set {OFF=0|ON=1}
ipacl ping enabled show
ipacl enabled set {OFF=0|ON=1}
ipacl enabled show
ipacl filter {ipacl_num} set "{dns_name}"
ipacl filter {ipacl_num} show
linesensor
linesensor all {field_list} show
linesensor {line_num} {field_list} show
linesensor {line_num} {energy_sensor} value
show
linesensor {line_num} ovp show
linesensor {line_num} counter reset
linesensor {line_num} label set "{name}"
linesensor {line_num} label show
linesensor {line_num} {energy_sensor} events
set {OFF=0|ON=1}
linesensor {line_num} {energy_sensor} events
show
linesensor {line_num} {energy_sensor} events
type set
"{EVT_SYSLOG=0,EVT_SNMP=1,EVT_EMAIL=2,E
VT_SMS=3,EVT_GSMEMAIL=4,EVT_BEEPER=5}"
linesensor {line_num} {energy_sensor} events
type show
linesensor {line_num} {energy_sensor} maxval
set {float}
linesensor {line_num} {energy_sensor} maxval
show
linesensor {line_num} {energy_sensor} minval set
{float}
linesensor {line_num} {energy_sensor} minval
show
linesensor {line_num} {energy_sensor} hyst set
{float}
linesensor {line_num} {energy_sensor} hyst
show
linesensor {line_num} {energy_sensor} publish
mode set {NONE=0|INTERVAL=1|DELTA=2|
INTERV_DELTA=3}
linesensor {line_num} {energy_sensor} publish
mode show
linesensor {line_num} {energy_sensor} publish
mqtt retain set {OFF=0|ON=1}
linesensor {line_num} {energy_sensor} publish
mqtt retain show
linesensor {line_num} {energy_sensor} publish
timer set {num_secs}
linesensor {line_num} {energy_sensor} publish
timer show
linesensor {line_num} {energy_sensor} publish
delta set {float}
linesensor {line_num} {energy_sensor} publish
delta show
linesensor {line_num} events set {OFF=0|ON=1} LEGACY - enables events on/off
linesensor {line_num} events show
linesensor {line_num} events type set
"{EVT_SYSLOG=0,EVT_SNMP=1,EVT_EMAIL=2,E
Expert PDU Energy 8311
show s manual IPv6 gatew ay address
sets manual IPv6 DNS server address
show s manual IPv6 DNS server address
enters cmd group "ipacl"
enables ICMP ping on/off
show s if ICMP ping enabled
enable IP filter on/off
show s if IP filter enabled
sets IP filter {ipacl_num}
show s IP filter {ipacl_num}
enters cmd group "linesensor"
show s energy sensors according field list of all
line sensors
show s energy sensors according field list of one
line sensor
show s energy sensor of given line
show state of Overvoltage Protection
resets energy metering counter
sets line meter to label
show s label of line meter
enables events on/off
show s if events are enabled
enables different event types
show s w hat event types are enabled
sets maximum value for line meter
show s maximum value for line meter
sets minimum value for line meter
show s minimum value for line meter
sets hysterese value for line meter
show s hysterese value for line meter
sets publish mode
show s publish mode
sets mqtt retain
show s if mqtt retain set
sets publish time interval
show s publish time interval
sets publish delta value
show s publish delta value
LEGACY - show s if events are enabled
LEGACY - enables different event types
3
3
5
5
5
L
L
L
66