OPERATING AND MAINTENANCE MANUAL
OPERATING INSTRUCTIONS
L Always use an impact wrench with the
tightening torque corresponding to the one
required by the application.
L If by mistake you have used a higher torque
than the one required:
⚪ in the case of screwing, replace the bolt
and reform the tread you screwed it onto,
because of it yielding;
⚪ in the case of unscrewing, replace the
bolt anyhow and check the tread you
screwed it onto.
ACCESSORIES ASSEMBLY
When changing accessory, always disconnect
the pressure lines.
Use only accessories suitable for the job.
MAINTENANCE
L Every three weeks clean the motor by
introducing naphtha (~25cc) through the
air inlet, while keeping the trigger pressed;
then running the wheel gun clockwise and
anticlockwise. After the inside washing,
repeat the previous operation with oil for
air tools (~5cc). These operations must be
performed in a suitably equipped working
environment, complete with extraction
equipment for nebulised particles. Use
personal protective equipment.
L Drain condensation at the air filter and the
compressor daily
(view figure
SCRAPPING
Separate the components on the basis of the nature of the materials of which they are made.
Translations of the original operating instructions
L If you have used a lower torque, screw
on again using an appliance with the
right torque, in order to avoid the risks of
insecure tightening.
L If you avoid operating at a higher pressure
than the one required you will save energy,
make less noise, and have less wear on the
appliance.
L "Square drive with hole and retainer ring":
Insert the accessory "A" in the square drive
of the tool, with an axial pressure, use the
pin "S" and the ring "R"
L Indicate the parts most subject to wear,
to be dismantled and checked at regular
intervals, as well as a list of malfunctions, if
any, and the corrective action.
L If the tool is left unused for long periods
we recommend putting some oil into the
air inlet and letting it run for a few seconds
before putting it away. In this way the internal
components will remain lubricated.
L Spare parts can be purchased in the "service
kit" package. Details of the service kit
components are available on our general
Fig.1).