Herunterladen Inhalt Inhalt Diese Seite drucken

Labelling, Safety Marks; Product Label; Ex Marking - WIKA FLM-CAI Betriebsanleitung

Magnetostriktiv-füllstandstransmitter für explosionsgefährdete bereiche
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3. Safety
3.7

Labelling, safety marks

Product label

EN
Model
Model code
Serial number
Article number
Tag no.
Ex-relevant data
Year of manufacture
3.8

Ex marking

DANGER!
Danger to life due to loss of explosion protection
Non-observance of these instructions and their contents may result in the loss
of explosion protection.
Check whether the classification is suitable for the application. Observe the relevant
national regulations.
12
Operating instructions magnetostrictive level transmitter, models FLM-xAI, BLM-TAI (Ex)
Ser. No.:
Art. No.:
Tag. No.:
IP68
Level Sensor ???????
Type: ???-????????????????
Ui=<30V; Pi=<1W; li=<200mA; Ci=<10nF; Li=<20µH
TÜV 18 ATEX 225120 X
II 1/2 G Ex ia IIC T6...T3 Ga/Gb
II 1 D Ex ia IIIC T160°C Da
Before mounting and commissioning the instrument, ensure you read the
operating instructions!
Observe the safety instructions in this chapter and further explosion
instructions in these operating instructions.
Observe the information given in the applicable type examination certificate
and the relevant country-specific regulations for installation and use in
hazardous areas (in Germany these are the explosion protection ordinance
(ExVo), the operational safety ordinance (BetrSichV), the product safety act
and the special requirements of the EC-type examination certificate).
max. DC 15 ... 30 V
WIKA Alexander Wiegand SE & Co. KG
Alexander-Wiegand-Strasse 30
63911 Klingenberg
????????????????
Bj.:????
WIKA Alexander Wiegand SE & Co. KG
Alexander-Wiegand-Strasse 30
63911 Klingenberg
4 ... 20 mA
0637
4-20 mA

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Flm-taiBlm-tai

Inhaltsverzeichnis