ENGLISH
Problem
Water flows on the floor.
The door does not close
completely.
Error code explanation
E1: Temperature sensor failure of the
refrigerator chamber
E2: Temperature sensor failure of the freezer
chamber
E3: Temperature sensor failure of the low
temperature chamber
E5: Defrosting sensor failure of the freezer
chamber
E6: Communication failure
E7: Failure of ambient temperature sensor
If your appliance still is not working
properly after making the above checks,
contact the Authorised Service Centre. You
can find the list at the end of this manual.
Possible Cause
The door is not closed well.
The appliance tilts forward.
The drip pan cracks.
The defrost water drain is clogged.
The shelves are out of position.
The door gaskets are dirty.
The appliance is not level.
Closing the door
1.
2.
3. If necessary, replace the defective door
Replacing the lamp
The appliance is equipped with a lamp for
interior lighting.
Only service is allowed to replace the lighting
device. Contact your Authorised Service Centre.
For quick solution, always refer to the full list
of Authorised Service Centre located at the
end of this manual and call your relative phone
number.
Refer to "Closing the door", or
refer to the troubleshooting item
below ("The door does not close
completely").
Tilt the appliance slightly backward
(a quarter-inch lower in the back).
Refer to the separate Assembly
Instructions for appliance level
adjustment.
Contact Authorised Service Centre
listed at the end of this manual.
Clean the drain hole with a piece
of wire.
Make sure the shelves are in
correct position. Refer to "Movable
shelves".
Clean the door gaskets.
Make sure the appliances
is installed in level. Refer to
"Levelling feet", or the separate
Assembly Instructions
Clean the door gaskets.
If necessary, adjust the door. Refer to the
separate Assembly Instructions.
gaskets. Contact the After Sales Service.
20
Solution