Herunterladen Inhalt Inhalt Diese Seite drucken

Conversions/Changes/Spare Parts; Interruption Of Operation; Fault - Conel CLEAR FILL PLUS Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Always store the resin bottle vertically after removing it from the heating circuit filling
station or cap!
When replacing a bottle, the cap of the replacement bottle is unscrewed. It can be
used on the consumed bottle to prevent water from running out.
/
Use the keypad to select the new bottle type (see chapter 6.3).
The display will now show the remaining capacity of the new bottle.
/
Install and bleed the new bottle (see chapter 5.4).
/
Completely open the upstream and downstream shut-off valves and continue the filling process if nec-
essary.
/
Dispose of the consumed bottle with general household rubbish.
6.8

CONVERSIONS/CHANGES/SPARE PARTS

Only original spare parts may be used!
Unauthorised conversions and changes are forbidden for safety reasons. These
can impair the functioning of the heating circuit filling station and cause leaks.
The imprinted approval marks are only valid if original spare parts are used.
6.9

INTERRUPTION OF OPERATION

To stop the flow of water to the heating circuit filling station, the upstream and downstream shut-off valves
must be closed.
When disassembled, the heating circuit filling station must be stored in a dry and frost-free location and
protected against contamination and damage.
7

FAULT

Opening of devices and replacement of parts subject to water pressure must only
be performed by licensed persons to ensure the safety and leak-tightness of the
devices.