Herunterladen Inhalt Inhalt Diese Seite drucken

Placing Tool In Service - Ingersoll-Rand 2906P-EU-Serie Gebrauchsanweisung

Hochleistungs-schlagschrauber
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 9
LUBRICATION
Ingersoll–Rand No. 50
Always use an air line lubricator with these tools.
We recommend the following Filter–Lubricator–Regulator
Unit:
For International – No. C26–C4–A29
After each eight hours of operation, unless an air line
lubricator is used, remove the Oil Chamber Plug and fill the
oil chamber with Ingersoll–Rand No. 50 Oil.
After each forty–eight hours of operation, or as experience
indicates, inject about 4 cc of Ingersoll–Rand No. 100 Grease
into the Grease Fitting.
Model
Type of
Handle
2906P1–EU
pistol
2906P7–EU
pistol
H
Tested in accordance with ANSI S5.1–1971 at free speed
♦ Tested to ISO8662–1 loaded with frictionbrake to 9 RPM

PLACING TOOL IN SERVICE

Ingersoll–Rand No. 100
SPECIFICATIONS
Drive
Impacts per
min.
in.
1/2" sq.
1,200
7/16" hex
1,200
recess
MAIN LINES 3 TIMES
AIR TOOL INLET SIZE
TO
AIR
SYSTEM
TO
AIR
TOOL
LUBRICATOR
REGULATOR
BRANCH LINE 2 TIMES
AIR TOOL INLET SIZE
DRAIN REGULARLY
Recommended
Torque Range
ft–lbs (Nm)
Pressure
40–350 (54.2–475)
83.7
40–350 (54.2–475)
83.7
3
FILTER
COMPRESSOR
(Dwg. TPD905–1)
HSound
Vibrations
Power Level
dB (A)
Power
– – –
– – –
Level
2
m/s
3.7
3.7

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis