ELECTRICAL CONNECTION

This appliance should only be installed and connected to the electrical system by a qualified
electrician.
Protection against live parts must be ensured after installation.
The required connection data can be found on the labels on the hob casing near the connection
box.
The connection to the mains must be made via an earthed plug or via an all-pole separator with
a contact opening of at least 3 mm.
The electric circuit must be separated from the mains by means of suitable devices, e.g: circuit
breakers, fuses or contactors.
If the appliance is not equipped with an accessible plug, separators must be installed in the
system in accordance with the installation instructions.
The input cable must be laid so that it does not touch any of the hot parts of the hob.
Caution!
This appliance may only be connected to a mains supply with 230 V/400 V ~ 50/60 Hz.
Always connect the earth cable.
Please observe the wiring diagram.
Mains
230V~50/60Hz
400V~ 50/60Hz
* calculated with the simultaneity factor according to the standard EN 60
335-2-6
Connection
1 phase + N
2 phases + N
Cable diameter
3 x 2.5 mm²
4 x 1.5 mm²
14
Protection
Cable
H 05 VV - F
H 05 RR - F
H 05 VV - F
H 05 RR - F
class
25 A *
16 A *