Problem
The cooling effect is not
good.
Loud noise
Compressor does not
work.
The remote control does
not work.
Error code E1
Error code E2
Possible cause
There is direct sunlight.
Doors or windows are
open, there are a lot of
people, or in cooling
mode, there are other
sources of heat (e.g.
fridges)
The filter screen is dirty.
The air inlet or outlet is
blocked.
The air conditioner is not
placed on a flat surface.
The overheat protection
has been activated.
The distance between the
appliance and the remote
control is too far.
The remote control is not
aligned with the direction
of the remote control
receiver.
The pipe temperature
sensor is abnormal.
The room temperature
sensor is abnormal.
Possible solution
Use curtains to reduce the
direct sun heat.
Close windows and
doors, increase the air
conditioning power and
remove heat sources if
possible.
Clean or replace the filter
screen.
Clear obstructions, make
sure venting is correct
as described in this user
manual and the hose is
not bent.
Put the air conditioning on
a flat and hard place (to
reduce noise).
Wait for 3 minutes until the
temperature is lowered,
and then restart the
appliance.
Make sure that the remote
control is used only near
the unit and that the
remote control points
directly toward the remote
control receiver.
Clean filters and restart.
Contact costumer service
centre if the issue still
persists.
Clean filters and restart.
Contact costumer service
centre if the issue still
persists.