12
the heat setting in 10 seconds. You can
operate the hob. When you deactivate the
hob with
the function operates again.
Power management
• Cooking zones are grouped according
to the location and number of the
phases in the hob. See the illustration.
• Each phase has a maximum electricity
loading of 3700 W.
• The function divides the power
between cooking zones connected to
the same phase.
• The function activates when the total
electricity loading of the cooking zones
connected to a single phase exceeds
3700 W.
• The function decreases the power to
the other cooking zones connected to
the same phase.
• The heat setting display of the reduced
zones changes between two levels.
Hob²Hood
It is an advanced automatic function which
connects the hob to a special hood. Both
the hob and the hood have an infrared
signal communicator. Speed of the fan is
defined automatically on basis of mode
setting and temperature of the hottest
cookware on the hob. You can also
operate the fan from the hob manually.
For most of the hoods the
remote system is originally
deactivated. Activate it before
you use the function. For more
information refer to hood user
manual.
Operating the function automatically
To operate the function automatically set
the automatic mode to H1 – H6. The hob
is originally set to H5. The hood reacts
whenever you operate the hob. The hob
recognizes temperature of the cookware
automatically and adjusts the speed of the
fan.
Automatic modes
Auto‐
matic
light
Mode
Off
H0
Mode
On
H1
Mode
On
3)
H2
Mode
On
H3
Mode
On
H4
Mode
On
H5
Mode
On
H6
1) The hob detects the boiling process and activates
fan speed in accordance with automatic mode.
2) The hob detects the frying process and activates
fan speed in accordance with automatic mode.
3) This mode activates the fan and the light and does
not rely on the temperature.
Boil‐
Fry‐
1)
2)
ing
ing
Off
Off
Off
Off
Fan
Fan
speed
speed
1
1
Off
Fan
speed
1
Fan
Fan
speed
speed
1
1
Fan
Fan
speed
speed
1
2
Fan
Fan
speed
speed
2
3