Bridging power supply
While changing the batteries, the charger provides
the vehicle with electricity (13,6 V±0,3 V, 7 A±1 A)
and no data is lost.
1. Connect the charger to the battery terminal.
2. Plug the charger plug into a 230V power socket.
3. Press the START /STOP button (3) for 5 seconds.
The „Power" LED (15) will light up. A voltage of
13.6V will be indicated in the display.
4. Remove the battery.
5. Insert a new battery.
6. Press the „START / STOP" button (3) to switch
off the bridging power supply.
7. Unplug from the 230V power socket.
8. Separate the charger from the battery terminal.
Charging time in hours (approx.)
Model
Charging current
(max.)
Battery
size
10 Ah
25 Ah
50 Ah
75 Ah
100 Ah
125 Ah
150 Ah
200 Ah
All manuals and user guides at all-guides.com
2 A
12 V / 24 V
7 h
17 h
33 h
49 h
65 h
82 h
98 h
130 h
Automatic temperature adjustment
Automatic tempe-
12 V
rature adjustment
±0.25 V
±2
º
C
≤ 7.5
C
15.25 V
º
7.5
C - 12.49
C
º
º
15.1 V
12.5
C - 17.49
C
14.95 V
º
º
17.5
C - 22.49
C
º
º
14.8 V
22.5
C - 27.49
C
14.65 V
º
º
27.5
C - 32.49
C
14.5 V
º
º
≥ 32.5
C
º
14.35 V
LT10
6 A
12 V / 24 V
2 h
6 h
11 h
16 h
21 h
26 h
32 h
42 h
English 25
24 V
±0.25 V
30.5 V
30.2 V
29.9 V
29.6 V
29.3 V
29.0 V
28.7 V
10 A
12 V
1,5 h
3 h
7 h
10 h
13 h
16 h
19 h
25 h