Technical Data

Digital Angle Measuring Device
Article number
Measuring range
Measuring accuracy
– Angle
– Spirit level
Calculated angle accuracy
Operating temperature
Storage temperature
Batteries
Rechargeable batteries
Operating life time, approx.
Automatic switch-off after approx.
Leg to leg length
Weight according to
EPTA-Procedure 01/2003
Dimensions
Please observe the article number on the type plate of your measur-
ing tool. The trade names of the individual measuring tools may vary.
The measuring tool can be clearly identified with the serial number
2 on the type plate.
Assembly
Inserting/Replacing the Battery (see figure A)
Using alkali-manganese or rechargeable batteries is recom-
mended for operation of the measuring tool.
Slide the battery compartment cover 5 in the direction of
the arrow and open it. Insert the batteries/rechargeable
batteries. When inserting, pay attention to the correct
polarity according to the representation on the inside of
the battery compartment.
When no batteries/rechargeable batteries were inserted in
the measuring tool for at least 5 minutes, the measuring tool
will switch on automatically after inserting the batteries/
rechargeable batteries and closing the battery compartment
cover 5. All indicator elements are displayed for approx. 5 s,
while the measuring tool carries out a self-check. Afterwards,
the current angle is displayed.
When the battery low indicator b is indicated the first time
in the display, measurements can be made for only about
1–2 hours.
When the battery low indicator b flashes, the batteries/
rechargeable batteries must be replaced. Measurements
are no longer possible.
Replace all batteries/rechargeable batteries at the same
time. Do not use different brands or types of batteries/
rechargeable batteries together.
Remove the batteries/rechargeable batteries from the
measuring tool when not using it for longer periods.
When storing for longer periods, the batteries/recharge-
able batteries can corrode and discharge themselves.
Bosch Power Tools

English | 15

GAM 220 MF
Professional
3 601 K76 200
0° –220°
±0.1°
1 mm/m
±0.1°
– 10 °C ... +50 °C
– 20 °C ... +70 °C
4x1.5 V LR6 (AA)
4x1.2 V KR6 (AA)
130 h
3 min
400 mm
1.1 kg
432 x 35 x 61 mm
1 609 929 T80 | (17.4.09)