TABELLA "B" - LOGICHE - (LOGIC)
Logic
Definition
Automatic Closing
TCA
Time
Switches to 3-step
3 step
logic
Block opening
ibl open
pulses
Pre-alarm
pre-alarm
Photocells during
Photoc.
opening
open
Photocell test
test phot
Gate open light or
SCA 2Ch
2nd radio channel
Fixed Code
fixed code
Remote control
radio prog
programming
START - OPEN
start-open
setting
PED-CLOSE setting
ped-close
Master/Slave
master
TABLE "C" – RADIO MENU (RADIO)
Logic
Description
Add Start Key
Add start
associates the desired key with the Start command
Add 2ch Key
associates the desired key with the 2nd radio channel command. Associates the desired key with the 2nd radio channel command. If no output
add 2ch
is configured as 2nd Radio Channel Output, the 2nd radio channel controls the pedestrian opening.
Erase List
WARNING! Erases all memorized transmitters from the receiver's memory.
erase 64
Read receiver code
Displays receiver code required for cloning transmitters.
ON = Enables remote programming of cards via a previously memorized W LINK transmitter.
It remains enabled for 3 minutes from the time the W LINK transmitter is last pressed.
OFF= W LINK programming disabled.
16 -
BOTTICELLI B CRC 480 D01
All manuals and user guides at all-guides.com
INSTALLATION MANUAL
Cross
out
Default
setting
used
Switches automatic closing on
ON
OFF
OFF
Switches automatic closing off
0N
Logic 3 step
OFF
OFF
Logic 4 step
The start pulse has no effect during opening.
ON
OFF
The start pulse has effect during opening.
OFF
The flashing light comes on approx. 3 seconds before the motor starts.
ON
OFF
The flashing light comes on at the same time as the motors start.
OFF
when beam is broken, operation of the photocell is switched off during opening. During clos-
ON
ing, movement is reversed immediately.
OFF
when beam is broken, photocells are active during both opening and closing. When beam is
OFF
broken during closing, movement is reversed only once the photocell is cleared.
Switches photocell testing on
ON
OFF
Switches photocell testing on
OFF
The output between terminals 14-15 is set as Gate open light: in this case, the 2nd radio channel
ON
controls partial opening.
OFF
The output between terminals 14-15 is set as 2nd radio channel.
OFF
Receiver is configured for operation in fixed-code mode, see "Radio transmitter cloning" section.
ON
OFF
Receiver is configured for operation in rolling-code mode, see "Radio transmitter cloning" sec-
OFF
tion.
Enables wireless memorizing of transmitters:
1- Press in sequence the hidden key (P1) and normal key (T1-T2-T3-T4) of a transmitter that has
already been memorized in standard mode via the radio menu.
2- Press within 10 sec. the hidden key (P1) and normal key (T1-T2-T3-T4) of a transmitter to be
ON
memorized.
ON
The receiver exits programming mode after 10 sec.: you can use this time to enter other new
transmitters.
This mode does not require access to the control panel.
Disables wireless memorizing of transmitters. Transmitters are memorized only using the rel-
OFF
evant Radio menu.
Input between terminals 3-4 works as OPEN
ON
OFF
Input between terminals 3-4 works as START.
OFF
Input between terminals 16-17 works as CLOSE.
ON
OFF
Input between terminals 16-17 works as PARTIAL OPENING.
OFF
Control panel is set up as the Master unit in a centralized connection system.
ON
OFF
Control panel is set up as a Slave unit in a centralized connection system.
OFF
Optional extras
step-by-step mov.
3 STEP
CLOSED
OPENS
DURING CLOSING
OPEN
CLOSES
DURING OPENING
STOP + TCA
AFTER STOP
OPENS
4 STEP
OPENS
STOPS
CLOSES
STOP + TCA
OPENS