CLEANING, STORAGE AND DISPOSAL
Do not clean the transducer with metal objects, abrasive tools
and/or chemicals.
Clean the outer surfaces of the appliance with a soft, damp cloth.
Do not use petroleum, thinners or any other chemicals.
Daily cleaning
1. T o avoid/reduce the formation of bacteria/minerals, clean the
appliance on a daily basis.
2. E mpty the water from the tank, fill it half full with cold tap
water, screw on the cap and shake the tank vigorously.
3. E mpty the water and rinse several times.
4. C lean the nebulisation chamber with a soft cloth and dry
thoroughly.
Weekly cleaning
1. Follow the instructions under 'Daily Cleaning' point 2 and 3.
2. Fill about half the tank with a solution of white vinegar and
water, screw on the cap and shake for a few minutes. Wait
about 20 minutes and shake briefly again. Empty the solution
and rinse several times. Allow the tank to dry completely
before using it again.
3. Remove water from the nebulisation chamber. To remove
the lime scale cover the transducer with a solution of vinegar
and water and leave it for at least 4 hours. Rinse with water
and dry thoroughly with a soft cloth.
Alternating current
Safety class: Class II, dual insulation equipment
Warning! Please read the instructions!
Room temperature -40 ÷ +70˚C
Relative humidity: 10 ÷ 95%
Approved to EC regulations and subsequent modifications
TROUBLESHOOTING
Q. T he ON/OFF light is ON, air comes out of the unit but
no steam.
A. C heck deposit of lime scale on the water level sensor
or transducer and if there is a visible build up, clean
the appliance.
Q. A strange smell emanates from the appliance.
A. C lean the water tank and nebulisation chamber by
following the 'Cleaning Instruction'. Aerate the water
tank and nebulisation chamber for 24 hours in a cool
place with the cap open.
DISPOSAL
P lease do not dispose of this product in the household
waste at the end of its useful life. Disposal can take place
at your local retailer or at appropriate collection points
provided.
This regulation is valid only in EU member states.
CONDITION OF PURCHASE
As condition of purchase the purchaser assumes responsibility for
the correct use and care of this KAZ product according to these
user instructions. The purchaser or user must himself or herself
decide when and for how long this KAZ product is in use.
WARNING: IF PROBLEMS ARISE WITH THIS KAZ PRODUCT,
PLEASE OBSERVE THE INSTRUCTIONS IN THE WARANTEE
CONDITIONS. DO NOT ATTEMPT TO OPEN OR REPAIR THE KAZ
PRODUCT YOURSELF, AS THIS COULD LEAD TO TERMINATION
OF THE WARANTEE AND CAUSE DAMAGE TO PERSONS AND
PROPERTY.
Technical modifications reserved.

TECHNICAL CHARACTERISTICS

Model : HH200E
Nominal Voltage : 230 V ~
Frequency: 50 Hz
Power : 25W
Fuse : T 2° 250V
Nebulising capacity : ≥ 180 ml / h
Water tank capacity : 5 Litres
Protection against liquids : normal
Type of equipment : Continuous operation
Safety class: Class II dual insulation equipment