Switch action
CAUTION:
• Before plugging in the tool, always check to see that
the switch trigger actuates properly and returns to the
"OFF" position when released.
For tool with type A switch trigger (For Models
GA5020, GA5020C, GA6020, GA6020C) (Fig. 2)
For tool without lock button and lock-off button
To start the tool, simply pull the switch trigger. Release
the switch trigger to stop.
For tool with lock button
To start the tool, simply pull the switch trigger. Release
the switch trigger to stop.
For continuous operation, pull the switch trigger and then
push in the lock button.
To stop the tool from the locked position, pull the switch
trigger fully, then release it.
For tool with lock-off button
To prevent the switch trigger from being accidentally
pulled, a lock-off button is provided.
To start the tool, depress the lock-off button and pull the
switch trigger. Release the switch trigger to stop.
For tool with type B switch trigger (For Models
GA5021, GA5021C, GA6021, GA6021C) (Fig. 3)
For tool with the lock-on switch
To start the tool, simply pull the switch trigger (A).
Release the switch trigger to stop. For continuous
operation, pull the switch trigger (A) and then push in the
lock lever (B). To stop the tool from the locked position,
pull the switch trigger (A) fully, then release it.
For tool with the lock-off switch
To prevent the switch trigger from accidentally pulled, a
lock lever is provided. To start the tool, push in the lock
lever (B) and then pull the switch trigger (A). Release the
switch trigger to stop.
For tool with the lock on and lock-off switch
To prevent the switch trigger from accidentally pulled, a
lock lever is provided. To start the tool, push in the lock
lever (B) and then pull the switch trigger (A). Release the
switch trigger to stop. For continuous operation, push in
the lock lever (B), pull the switch trigger and then push the
lock lever further in (B). To stop the tool from the locked
position, pull the switch trigger (A) fully, then release it.
Electronic function
Constant speed control (For models GA5020C,
GA5021C, GA6020C, GA6021C)
• Possible to get fine finish, because the rotating speed
is kept constantly even under the loaded condition.
• Additionally, when the load on the tool exceeds
admissible levels, power to the motor is reduced to
protect the motor from overheating. When the load
returns to admissible levels, the tool will operate as
normal.
Soft start feature
• Soft start because of suppressed starting shock.
8
All manuals and user guides at all-guides.com
Indication lamp (Fig. 4)
The indication lamp lights up green when the tool is
plugged. If the indication lamp does not light up, the mains
cord or the controller may be defective. The indication
lamp is lit but the tool does not start even if the tool is
switched on, the carbon brushes may be worn out, or the
controller, the motor or the ON/OFF switch may be
defective.
Unintentional restart proof
Even locking lever keeping the switch trigger depressed
(Lock-on position) does not allow the tool to restart even
when the tool is plugged.
At this time, the indication lamp flickers red and shows the
unintentional restart proof device is on function.
To cancel the unintentional restart proof, pull the switch
trigger fully, then release it.
ASSEMBLY
CAUTION:
• Always be sure that the tool is switched off and
Installing side grip (handle) (Fig. 5)
CAUTION:
• Always be sure that the side grip is installed securely
Screw the side grip securely on the position of the tool as
shown in the figure.
Installing loop handle (Optional
accessory)
CAUTION:
• Always be sure that the loop handle is installed
Always install the loop handle on the tool before
operation. Hold the tool's switch handle and the loop
handle firmly with both hands during operation.
Install the loop handle so that its protrusion will fit into the
matching hole in the gear housing.
Install the bolts and tighten them with the hex wrench.
The loop handle can be installed in two different directions
as shown in the figures whichever is convenient for your
work. (Fig. 7 & 8)
Installing or removing wheel guard (For
depressed center wheel, multi disc/
abrasive cut-off wheel, diamond wheel)
CAUTION:
• When using a depressed center grinding wheel/Multi-
For tool with locking screw type wheel guard (Fig. 9)
Mount the wheel guard with the protrusion on the wheel
guard band aligned with the notch on the bearing box.
Then rotate the wheel guard around 180 degrees
counterclockwise. Be sure to tighten the screw securely.
To remove wheel guard, follow the installation procedure
in reverse.
unplugged before carrying out any work on the tool.
before operation.
securely before operation. (Fig. 6)
disc, wire wheel brush or cut-off wheel, the wheel
guard must be fitted on the tool so that the closed side
of the guard always points toward the operator.