Vacuum Adapter Removal
NOTE: Press and hold the projection
on the bottom of the vacuum adapter
before pulling it out of the machine.
OPERATION
Pendulum Function
Safety On/Off Switch
NOTE: For safety reasons the On/
Off switch of the machine cannot
be locked; it must remain pressed
during the entire operation.
Increasing or reducing the pressure
on the On/Off switch enables
stepless stroke-rate control of the
switched-on machine.
Straight Cut and Curve Cut
Bevel Cut
NOTE: Remove the vacuum adapter
before adjust the base plate.
NOTE: Rotate the base plate to the
desired position according to the
scale. Ensure the blade is engaged
between the blade positioning wheel
.
12
12
Plunge Cut
5. WORKING HINTS FOR
YOUR JIGSAW
If your power tool becomes too hot, please run your
jigsaw no load for 2-3 minutes to cool the motor. Avoid
prolonged usage at very low speeds.
Always use a blade suited to the material and material
thickness to be cut. For tight curves it is best to use
a narrow saw blade. When sawing metal or similar
materials, apply coolant/lubricant alongside the
cutting line.
Always ensure the workpiece is firmly held or clamped
to prevent movement. Any movement of the material
may affect the quality of the cut. The blade cuts on the
upward stroke and may chip the uppermost. Ensure
your uppermost surface is a non-visible surface when
your work is finished.
For easier control, use low speed to start cutting and
then increase to correct speed.
In order to avoid operation malfunctions, do not saw
gypsum board from below or overhead.
The guide roller should occasionally be checked for
wear and lubricated with a drop of oil. If it is worn, it
must be replaced.
Cordless Jigsaw
6. MAINTENANCE
See Fig. B4
Remove the battery pack from the tool before carrying
out any adjustment, servicing or maintenance.
There are no user serviceable parts in your power
tool. Never use water or chemical cleaners to clean
your power tool. Wipe clean with a dry cloth. Always
store your power tool in a dry place. Keep the motor
See Fig. C
ventilation slots clean. Keep all working controls free
of dust. Occasionally you may see sparks through the
ventilation slots. This is normal and will not damage
your power tool.
FOR BATTERY TOOLS
See Fig. D
The ambient temperature range for the use and
storage of tool and battery is 0°C-45°C.
The recommended ambient temperature range for the
charging system during charging is 0°C-40°C.
See Fig.
E1, E2
7. TROUBLESHOOTING
Symptom
See Fig.
F, G
The tool
suddenly
stops
See Fig. H
during
operation.
8. ENVIRONMENTAL
PROTECTION
Waste electrical products must not be disposed
of with household waste. Please recycle where
facilities exist. Check with your local
authorities or retailer for recycling advice.
Possible
Possible Solution
Causes
Overload
Relieve the load
Battery
on the machine
temperature
immediately and
too high
allow cooling for
approx. 30 seconds
by running the
machine on no-load.
Low battery
Charge the battery
capacity
pack.
EN