Herunterladen Inhalt Inhalt Diese Seite drucken

wtw EcoLine pH 170 Bedienungsanleitung Seite 200

Meßumformer
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Redox measurement
Redox measurement
Redox signal input
Redox signal input
Display and measuring
Display and measuring
range
range
Measured value resolution
Measured value resolution
Accuracy
Accuracy
Temperature
Temperature
measurement
measurement
Temperature sensor
Temperature sensor
Accuracy
Accuracy
Resolution
Resolution
Inputs / outputs
Inputs / outputs
Sensor input
Sensor input
Contact outputs
Contact outputs
Signal outputs
Signal outputs
Connector terminals
Connector terminals
204
204
Technical Data
Technical Data
Low impedance or high impedance
Low impedance or high impedance
– 1000 mV to + 1000 mV
– 1000 mV to + 1000 mV
1 mV
1 mV
± 2 mV ± 1 digit
± 2 mV ± 1 digit
• NTC (integrated in SensoLyt or external armatures)
• NTC (integrated in SensoLyt or external armatures)
• PT 100 (3-line technology, direct via terminals)
• PT 100 (3-line technology, direct via terminals)
• PT 1000 (3-line technology, direct via terminals)
• PT 1000 (3-line technology, direct via terminals)
• NTC
• NTC
• PT100/PT 1000
• PT100/PT 1000
Additional fine adjustment of ± 0.5 K
Additional fine adjustment of ± 0.5 K
0.1 K
0.1 K
7-contact round plugconnector with screw fixing
7-contact round plugconnector with screw fixing
SENS-CHECK relay
SENS-CHECK relay
Relay 1/ Relay 2
Relay 1/ Relay 2
• Max. switching voltage 250 VAC
• Max. switching voltage 250 VAC
• Max. switching current 5 A
• Max. switching current 5 A
• Max. switching capacity 150 W (ohmic load)
• Max. switching capacity 150 W (ohmic load)
0/4 to 20 mA; electrically isolated from the input;
0/4 to 20 mA; electrically isolated from the input;
recorder ranges and recorder attenuation can be set
recorder ranges and recorder attenuation can be set
via software
via software
• Basic accuracy
• Basic accuracy
• Load
• Load
• Load effect
• Load effect
Accessible after opening the instrument;
Accessible after opening the instrument;
Cable inlet by 4 PG screws
Cable inlet by 4 PG screws
Connector cross section 0.5 to 2.5 mm²
Connector cross section 0.5 to 2.5 mm²
• Power supply
• Power supply
• Relay 1/2
• Relay 1/2
• SENS Check
• SENS Check
• Recorder connections each 2-contact
• Recorder connections each 2-contact
• Sensor
• Sensor
± 0.2 K ± 1 digit
± 0.2 K ± 1 digit
± 0.1 K ± 1 digit
± 0.1 K ± 1 digit
Closes on sensor defect
Closes on sensor defect
Functions, limit controller
Functions, limit controller
0.1%
0.1%
max. 600 Ohm
max. 600 Ohm
< 0.1 %
< 0.1 %
2-contact
2-contact
each 2-contact
each 2-contact
2-contact
2-contact
9-contact
9-contact

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Quadroline ph 296

Inhaltsverzeichnis