7. PROGRAMMING
7.7.15b Password Use
1. Choose "PS" function and press "P" button.
2. "00" flashes on display.
3. Use "+" and "–" buttons to enter the correct password and press "P" button to
confirm.
4. If correct password is entered, the display shows the value for 2 seconds and
changes to "PS".
5. Choose the protected function to set.
NOTE: If entered password is not correct, "00" will flash for 5 seconds, then
change to "PS". Use correct password to access protected Functions.
Attention: The password protected Advanced Settings can only be executed by a
trained professional. The requirements of the EU: EN 12453, EN 13241; GB (UK,
NI): BS EN 12453, BS EN 13241 must be fulfilled.
7.7.15c Password Change
1. Choose "PS" function and press "P" button.
2. "00" flashes in display.
3. Use "+" or "–" buttons to enter current password and press "S" button. Value
starts flashing.
4. Use "+" or "–" buttons to enter NEW password and press "P" button.
5. Changed password value remains on display for 2 seconds. Then display
changes to "PS".
NOTE: If wrong (current) password was entered, "00" will flash for 5 seconds and
change to "PS". Password is not changed.
If password is lost, use Factory Default function (Fd) to go back to default settings.
All settings (apart from Radio Memory) will be deleted. See page 18.
7.7.15d Force Motors 1 and 2 in Open and Close Directions
Force Motor 1 in OPEN Direction
Force Motor 1 in OPEN direction allows force adjustment on top of force set during
the Learning phase. Password must be entered to access this function.
Standard force (Default)
+15%
Force Motor 1 in CLOSE Direction
Force Motor 1 in CLOSE direction allows force adjustment on top of force set
during the Learning phase. Password must be entered to access this function.
Standard force (Default)
+15%
Force Motor 2 in OPEN Direction
Force Motor 2 in OPEN direction allows force adjustment on top of force set during
the Learning phase. Password must be entered to access this function.
Standard force (Default)
+15%
Force Motor 2 in CLOSE Direction
Force Motor 2 in CLOSE direction allows force adjustment on top of force set
during the Learning phase.Password must be entered to access this function.
+30%
+50%
7.7.15e Speed Motors 1 and 2 in Open and Close Directions
Speed Motors 1 and 2 in OPEN Direction
Speed Motor 1 and 2 in OPEN direction allows opening speed adjustment compa-
red to the speed set during Learning phase. Password must be entered to access
this function.
+30%
+50%
+30%
+50%
17
S
P
+
S
P
+
S
P
+
S
P
+
S
P
+
S
P
+
S
P
+
2 sec.
Standard force (Default)
+15%
Standard speed (Default)
+10%
+20%
+30%
2 sec.
or
or
+30%
+50%
+50%
-10%
-20%